Division 9 Ebook Page 98 Metro Rebound Panels

PART 1 GENERAL 1.1 Work in this section shall be subject to drawings, general conditions, schedules, addenda and other contract documents. 1.2 The extent of the acoustical panels is shown on the drawings and in the schedules. 1.3 Submit _______ (select quantity) samples of each type of acoustical panel as shown on the drawings and in schedules and include appropriate technical information including test data and maintenance instructions. Submit __________ (select quantity) fabric selector cards from manufacturer's standard finishes, or designer specified finishes. 1.4 Acoustical panels shall be installed according to manufacturer's recommendations and instructions. 1.5 Installation of acoustical panels shall not begin until all wet work (plastering, concrete, etc.) is completed and dry. Building shall be properly enclosed and under standard occupancy conditions (temperature of 60-85 F and not more than 70% relative humidity) before installation begins. 1.6 The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to the acoustical panel installation. 1.7 Substitutions or changes will only be permitted by prior approval by the architect. PART 2 MATERIALS 2.1 Metro Rebound panels shall be: Metro Rebound panels as manufactured by Conwed Designscape Wall Technology, 800 Gustafson Road, Ladysmith, WI 54848. Phone (800) 932-2383, fax (800) 833-4798. 2.2 Acoustical Panels shall be constructed of a composite core construction of dimensionally stable rigid fiberglass of medium 6-7 PCF density, laminated to a 1 /16" resilient perforated co-polymer face sheet. Thickness (choose one) 1- 1 /16", 1- 9 /16", 2- 1 /16" or custom __________ (specify). 2.3 Sizes: ______ width and _______ high or as shown on drawings. Standard maximum size is 48" wide x 116" high (nominal). Custom or larger sizes up to 51" widths are available; consult manufacturer. Panels are to be manufactured according to field dimensions supplied by the installing contractor. Standard tolerances are 1 /16" in width and length. 2.4 Edge profile shall be square. Corner detail shall be square. Edge treatment shall be resin hardened beneath heat-formed co-polymer. 2.5 Panel finish shall be ______________________________ ________ (specify co-polymer color). Co-polymer shall be applied directly to face and edges of the panel. 2.6 Mounting shall be: Adhesive/Resin, Impaling/Adhesive, Lay-in, Magnet, VELCRO, Panel Clip to Z-Bar, Panel Clip to Double Wall Clip, Z-Bar to Z-Bar (recommended for ceilings), Aluminum Z-Clips, Panel Clips/VELCRO or custom ________________ (specify). Adhesive, miscellaneous fasteners, (i.e. nails, screws, etc.) and standard continuous wall leveling angle are to be supplied by the contractor. 2.7 Acoustical Performance - panels shall have a minimum NRC of _____ (please specify) in accordance with ASTM C-423 Test Procedure. 2.8 Flammability - All panel components shall have a Class "A" fire rating in accordance with ASTM E-84. 2.9 R-Value is _____. (Calculated using the R-factor of 4.16 per inch of thickness.) Thank you for choosing Conwed Designscape Wall Technology for your acoustical needs. The information provided above is correct to the best of our knowledge at time of printing. We reserve the right to make changes without prior notification. DISCLAIMER OF LIABILITY Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. Nothing contained in this bulletin shall be considered a recommendation. Product Data Sheet &'& &25325$7,21 800 Gustafson Road Ladysmith, Wisconsin 54848 T: 1-800-932-2383 F: 1-800-833-4798 www.conweddesignscape.com Pub. No. 10018122-A. Printed in U.S.A. April 2014. 2014 Owens Corning. All Rights Reserved. LEED is a registered trademark of U.S. Green Building Council. METRO REBOUND PANELS

Previous Page
Next Page