Division 9 Ebook Page 90 Skyway’ Ceiling Clouds Type I

Product Data Sheet &'& &25325$7,21 800 Gustafson Road Ladysmith, Wisconsin 54848 T: 1-800-932-2383 F: 1-800-833-4798 www.conweddesignscape.com Pub. No. 10018364-A. Printed in U.S.A. April 2014. 2014 Owens Corning. All Rights Reserved. LEED is a registered trademark of U.S. Green Building Council. SKYWAY CEILING CLOUDS TYPE I PART 1 GENERAL 1.1 Work in this section shall be subject to drawings, general conditions, schedules, addenda and other contract documents. 1.2 The extent of the acoustical panels is shown on the drawings and in the schedules. 1.3 Submit _______ (select quantity) samples of each type of acoustical panel as shown on the drawings and in schedules and include appropriate technical information including test data and maintenance instructions. Submit __________ (select quantity) fabric selector cards from manufacturer's standard finishes, or designer specified finish. 1.4 Acoustical panels shall be installed according to manufacturer's recommendations and instructions. 1.5 Installation of acoustical panels shall not begin until all wet work (plastering, concrete, etc.) is completed and dry. Building shall be properly enclosed and under standard occupancy conditions (temperature of 60-85 F and not more than 70% relative humidity) before installation begins. 1.6 The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to the acoustical panel installation. 1.7 Substitutions or changes will only be permitted by prior approval by the architect. PART 2 MATERIALS 2.1 Acoustical ceiling panels shall be: Skyway Ceiling Clouds Type I as manufactured by Conwed Designscape Wall Technology, 800 Gustafson Road, Ladysmith, WI 54848. Phone (800) 932-2383, fax (800) 833-4798. 2.2 Acoustical panels shall be constructed of a composite core construction of dimensionally stable rigid fiberglass of medium density laminated to 1/8" molded fiberglass. Absorptive thickness: shall be (choose one) 1-1/8", 1-5/8" or 2-1/8". 2.3 Sizes: ____ width and _____high or as shown on drawings. Standard maximum is 48" x 120". Custom shapes are available. Panels are to be manufactured according to field dimensions supplied by the installing contractor. Standard tolerances are 1/16" in width and length. 2.4 Edge profile shall be square, bevel (1/2" or more) or custom__________(specify). Corner detail shall be Square or radius 2.5 Panel finish shall be ___________________________ ______________ (specify finish manufacture, pattern color and specifier). Finish shall be applied directly over the face and edges and returned to the back to provide a full finished edge. All corners are fully tailored. Optional backing includes fabric or scrim (specify). 2.6 Standard mountings shall be resin spots for either field applied self-drilling acoustical anchors or ceiling grid mains (by others). Both are attached via wire or cable (by others). (Please specify). 2.7 Acoustical Performance: panels shall have a minimum NRC of_____(please specify) in accordance with ASTM C-423. 2.8 Flammability: All panel components shall have a Class "A: fire rating in accordance with ASTM E-84. Thank you for choosing Conwed Designscape Wall Technology for your acoustical needs. The information provided above is correct to the best of our knowledge at time of printing. We reserve the right to make changes without prior notification. DISCLAIMER OF LIABILITY Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. Nothing contained in this bulletin shall be considered a recommendation.

Previous Page
Next Page