Division 9 Ebook Page 74 RespondŽ IR Series Acoustical Panels

Product Data Sheet RESPOND IR SERIES IR108/IR308/IR408 &'& &25325$7,21 800 Gustafson Road Ladysmith, Wisconsin 54848 T: 1-800-932-2383 F: 1-800-833-4798 www.conweddesignscape.com Pub. No. 10018114-A. Printed in U.S.A. April 2014. 2014 Owens Corning. All Rights Reserved. LEED is a registered trademark of U.S. Green Building Council. PART 1 GENERAL 1.1 Work in this section shall be subject to drawings, general conditions, schedules, addenda and other contract documents. 1.2 The extent of the acoustical panels is shown on the drawings and in the schedules. 1.3 Submit _______ (select quantity) samples of each type of acoustical panel as shown on the drawings and in schedules and include appropriate technical information including test data and maintenance instructions. Submit __________ (select quantity) fabric selector cards from manufacturer's standard finishes, or designer specified finishes. 1.4 Acoustical panels shall be installed according to manufacturer's recommendations and instructions. 1.5 Installation of acoustical panels shall not begin until all wet work (plastering, concrete, etc.) is completed and dry. Building shall be properly enclosed and under standard occupancy conditions (temperature of 60-85F and not more than 70% relative humidity) before installation begins. 1.6 The contractor shall be responsible for the examination and acceptance of all surfaces and conditions prior to the acoustical panel installation. 1.7 Substitutions or changes will only be permitted by prior approval by the architect. PART 2 MATERIALS 2.1 Acoustical wall panels shall be: Respond IR Series Acoustical Wall Panels as manufactured by Conwed Designscape Wall Technology, 800 Gustafson Road, Ladysmith, WI 54848. Phone (800) 932-2383, fax (800) 833-4798 2.2 Acoustical Panels shall be constructed of a composite core construction of dimensionally stable rigid fiberglass of 6-7 pcf density laminated to 1 /8" 16-20 pcf molded glass fiber. Thickness (choose one) ", ", 1", 1-", 2", 3", 4" plus 1 /8" or custom ________(specify). 2.3 Sizes: ______ width and _______ high or as shown on drawings. Standard maximum size is 4' x 12' or 5' x 10' (nominal) for 1", 2" and 3". 4' x 10' is the maximum size for ", " and 1-". 4" is limited (by weight) to 24 square feet; either 4' x 6' or 2' x 12' or custom. Panels are to be manufactured according to field dimensions supplied by the installing contractor. 2.4 Edge profile shall be: Square, radius, full bevel, half- bevel, miter, or custom __________________ (specify). Corner detail shall be: Square, radius or custom _______________ (specify). Edge treatment shall be: resin hardened, aluminum or high-pressure laminate (with square edge only), wood (all profiles available) or custom ____________ (specify). 2.5 Panel finish shall be _________________________ ____________ (specify finish manufacturer, pattern, color and specifier). Finish shall be applied directly over the face and edges of the panel and returned to the back of the panel to provide a full finished edge. All corners are fully tailored. 2.6 Mounting shall be: Adhesive/Resin, Adhesive No Resin, Impaling/Adhesive, Lay-in, Magnet, Spline, VELCRO , Panel Clip to Z-Bar, Panel Clip to Double Wall Clip, Z-Bar to Z-Bar, Aluminum Z-Clips, Panel Clips/VELCRO or custom ____________ (specify). Adhesive, miscellaneous fasteners, (i.e. nails, screws, etc.) and standard continuous wall leveling angle are to be supplied by the contractor. 2.7 Acoustical Performance - panels shall have a minimum NRC of _____ (please specify). 2.8 Flammability - All panel components shall have a Class "A" fire rating in accordance with ASTM E-84. 2.9 R-Value is _____. (Calculated using the R-factor of 4.16 per inch of thickness.) Thank you for choosing Conwed Designscape Wall Technology for your acoustical needs. The information provided above is correct to the best of our knowledge at time of printing. We reserve the right to make changes without prior notification. DISCLAIMER OF LIABILITY Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. Nothing contained in this bulletin shall be considered a recommendation.

Previous Page
Next Page