Division 9 Ebook Page 7 Rebound Panels

Rebound Panels 2. Core Fiberglass Density: 6 - 7 pcf. 3. Cores laminated with 1/16 inch thick, resilient perforated co-polymer face sheet. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 1-1/16 inches. 6. Core Thickness: 1-9/16 inches. 7. Core Thickness: 2-1/16 inches. 8. Width: 24-48 inches and custom widths up to 53 inches. 9. Length: 24-120 inches and custom. 10. Corners: Square. 11. Corners: Radiused. 12. Edge Profile: Square. 13. Edge Profile: Miter for corner conditions. 14. Edge Treatment: Resin hardened. 15. Edge Treatment: Aluminum for square edge only. 16. Edge Treatment: High-pressure laminate, for square edge only. 17. Corners: Fully tailored. 18. Finish: Manufacturer, type and color as selected. 19. Mounting Type: Adhesive / Resin. 20. Mounting Type: Adhesive No Resin. 21. Mounting Type: Impaling / Adhesive. 22. Mounting Type: Lay-in. 23. Mounting Type: Magnet. 24. Mounting Type: Spline. 25. Mounting Type: Velcro. 26. Mounting Type: Panel Clip to Z-Bar. 27. Mounting Type: Panel Clip to Double Wall Clip. 28. Mounting Type: Z-Bar to Z-Bar. 29. Mounting Type: Aluminum Z-Clip. 30. Mounting Type: Panel-Clip / Velcro. 31. Flammability (ASTM E 84): Panel components shall have a Class "A" rating per ASTM E 84. 32. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 33. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5 Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/16 inch Thickness: 0.85. PART 3 - EXECUTION 3.1 INSTALLATION A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installer's acceptance of surfaces and conditions. B. Install products in accordance with manufacturer's written instructions and in proper relationship with adjacent construction, including the following: 1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries. C. Touch-up, repair or replace damaged units until satisfactory results are obtained. END OF SECTION 2014 Owens Corning. All Rights Reserved.

Previous Page
Next Page