Division 9 Ebook Page 59 Eurospan® Translucence Ceiling System Specification

Eurospan Translucence System PART 2 - PRODUCTS 2.1 MANUFACTURER A. Stretched Fabric Ceiling Systems: Eurospan Translucence Stretch Fabric System as manufactured by Eurospan Stretch Systems, www.eurospanstretchsystems.com with the following characteristics: 1. Fabric: Eurospan Classic or EOS fabric, [standard white] color. a. Fabric Type- Classic - Fiber content and locking weave not affected by heat or humidity, spot cleanable and dry cleanable. EOS - added light polyurethane coating b. Fabric Size: No seams up to 16 feet; seams allowed over 16 feet. c. Fire Performance: NFPA Class A or UBC Class I, ASTM E84 flame spread index 5 or less and smoke developed 15 or less. d. Light Reflectance: Minimum light reflectance of 0.75 - 0.85 2. Fabric Mounting Devices: Nominal 1/2 inch or 1 inch fire-retardant rigid polymer high-strength extrusions produced in perimeter and mid-seam profiles. Attachment: mechanical fasteners with ability to attach extrusions to frames or suitable substrate. a. Fire Performance, Assembly: NFPA Class A or UBC Class I, ASTM E84 flame spread index 5 or less and smoke developed 35 or less. b. Perimeter Track: [Square] with exposed edges selective covered with matching fabric or painted to match the fabric. c. Mid Joint Track: [Square] track as required to achieve design indicated on the Drawings. System is also capable of installing panels continuously without joints. PART 3 - EXECUTION 3.1 EXAMINATION A. Verification of Conditions: Examine installation location and conditions under which work is to be performed. Verify wet work is complete and dry. Verify suitable blocking is in place. Notify Contractor in writing of any unsatisfactory conditions. Do not proceed until satisfactory conditions are achieved. 3.2 INSTALLATION A. Install products in accordance with manufacturer's written instructions and in proper relationship with adjacent construction including the following: 1. Inspect fabric prior to installation. Do not install damaged, imperfect or soiled fabric. 2. Anchor stainless steel cable fittings to structure, using anchors acceptable to the manufacturer. 3. Stretch fabric and secure into the cable fittings to produce a smooth surface, free of wrinkles or puckers. Adjust fabric to meet the required dimensional layout. 3.3 CLEANING AND PROTECTION A. Clean exposed surfaces as necessary. Comply with manufacturer's instructions for cleaning and repair of minor finish damage. Remove and replace work that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage. B. Advise Contractor of required protection, including soiling from other trades and dust control, so that the work will be without damage and deterioration at the time of acceptance. END OF SECTION 2014 Owens Corning. All Rights Reserved.

Previous Page
Next Page