Division 9 Ebook Page 58 Eurospan® Translucence Ceiling System Specification

Eurospan Translucence System PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise. SECTION 09 54 43 - STRETCHED TRANSLUCENT FABRIC CEILING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Stretched fabric ceiling system, consisting of translucent fabric membrane stretched and fastened to fixed or demountable frame structures in place below ambient or artificial lighting. 1.2 SUBMITTALS A. Product Data: Submit manufacturer's product data including certified laboratory test reports and other data required to show compliance with these specifications. B. Shop Drawings: Submit shop drawings showing typical reflected ceiling plan, sectional views and details of construction. C. Samples: Submit 12 by 12 inch samples of representative fabric with factory detailed edge, and representative samples of stainless steel cables and fittings to be used as mounting devices. D. Certified Test Reports: Submit test data from an independent testing agency, acceptable to authorities having jurisdiction, evidencing that systems components comply with requirements indicated for fire performance characteristics. Submit test data from independent testing agencies showing that system complies with the specified requirements for acoustical performance. E. Extra Stock: Submit an additional 2 percent of each fabric as extra stock for future use. 1.3 QUALITY ASSURANCE A. Installer Qualifications: Owens Corning Certified Installer. 1.4 DELIVERY, STORAGE, AND HANDLING A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium. 1.5 LIMITED WARRANTY A. Limited Warranty: Provide manufacturer's standard limited 2-year warranty against defects in materials and manufacturing. Provide manufacturer's standard limited 10-year warranty against sagging or wrinkles due to heat, humidity or aging.

Previous Page
Next Page