Respond Baffles: Fold-Up and Back-to-Back 2. Core Fiberglass Density: 6 - 7 pcf. 3. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 4. Core Thickness: 1 inch. 5. Core Thickness: 1-1/2 inches. 6. Core Thickness: 2 inches. 7. Width for Fold-Up Baffles: 24-72 inches and custom. 8. Height for Fold-Up Baffles: 24-96 inches and custom 9. Width for Back-to-Back Baffles: 24-120 inches and custom. 10. Height For Back-to-Back Baffles: 24-120 inches and custom. 11. Corners: Square. 12. Edge Profile for Fold-up Baffles: Square. 13. Edge Profile for Back-to-Back Baffles: Square. 14. Edge Profile for Back-to-Back Baffles: Radius. 15. Edge Profile for Back-to-Back Baffles: Full-bevel. 16. Edge Profile for Back-to-Back Baffles: Half-bevel. 17. Edge Treatment for Fold-up Baffles: Resin hardened. 18. Edge Treatment for Back-to-Back Baffles: Resin hardened. 19. Fabric Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panels to provide full finished edge, fully tailored corners. 20. Mounting For Fold-up Baffles: Vertical attachment to D-Rings. 21. Mounting For Back-to-Back Baffles: Vertical attachment to D-Rings. 22. Flammability (ASTM E 84): Panel components shall have a Class "A" rating per ASTM E 84. 23. Acoustical Performance: Values below are for baffles mounted in accordance with ASTM C 423 (Type D5 Mounting) and vary by baffle thickness and finish. a. Performance for 1 inch thickness: 1.3 Sabins/sf. b. Performance for 2 inch thickness: 1.75 Sabins/sf. PART 3 - EXECUTION 3.1 INSTALLATION A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installer's acceptance of surfaces and conditions. B. Install products in accordance with manufacturer's written instructions and in proper relationship with adjacent construction, including the following: 1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.. C. Touch-up, repair or replace damaged units until satisfactory results are obtained. END OF SECTION 2014 Owens Corning. All Rights Reserved.

Previous Page
Next Page