Division 9 Ebook Page 157 QuietZone Acoustic Floor Mat Product Data Sheet

Installation Instructions QuietZone Acoustic Floor Mat Butt adjoining edges of floor mat against each other and tape all seams with standard (2" wide) building tape. Cut a strip of QuietZone Acoustic Floor Mat 3-4" wide and place strip along wall and tape edge to the floor mat on the subfloor. NOTE : Floor mat strip should form a sealed, right angle with the floor mat on the subfloor. Tape the top of the perimeter strip to the wall so that the gypsum concrete can fill the entire floor surface area. Ensure the QuietZone Acoustic Floor Mat is free of any tears or punctures. 2. Install Gypsum Concrete Raft on Top of Floor Mat Pour the lightweight gypsum Figure 1 Wood Frame Construction CAUTION: COMBUSTIBLE. This product should not be exposed to open flames or other possible ignition sources. It may contain flammable vapors and should be stored in well ventilated areas. Further processing of the product may result in the localized release of flammable vapors. This product should be installed in such a way that it is separated from the building interior by a thermal barrier. Typical thermal barriers are a minimum of 5 8 " plywood or 1" thick concrete. Please refer to the Material Safety Data Sheet for more information. 2 layers of 3 8 " exterior grade plywood 1" reinforced mortar bed 3 8 " Owens Corning QuietZone Acoustic Floor Mat " Plywood Subfloor 2"x10" wood joists, 16" o.c. QuietZone Acoustic Batt Resilient Channel 24" o.c. 2 layer, 5 8 " Resilient Gypsum Ceiling Wood Parquet Flooring Tile Flooring Acoustic Testing completed by the National Research Council of Canada. Acoustic Testing completed by the National Research Council of Canada. Passed Heavy Rating when tested in accordance with ASTM C 627 by the Tile Council of America. STC-63 IIC-55 STC-73 IIC-63 Figure 2 Concrete Slab Construction 1" reinforced mortar bed 3 8 " Owens Corning QuietZone Acoustic Floor Mat 6" Reinforced concrete slab QuietZone Acoustic Batt Insulation 5 8 " Resilient Gypsum Ceiling Finished Flooring Acoustic Testing completed by Riverbank Acoustical Laboratories. Finished Flooring STC IIC Vinyl RAL-TL99-213; RAL-IN99-18 59 Laminate Wood RAL-TL99-214; RAL-IN99-19 59 58 Tile 1 RAL-TL88-217; RAL-IN99-17 58 57 1 Passed Light Commercial Rating when tested in accordance with ASTM C 627 by the Tile Council of America. Plywood Raft: Two staggered layers of 3 8 " exterior, AC-grade plywood (use two layers of " plywood when installing hardwood flooring). Finished Flooring QuietZone Acoustic Floor Mat Sub-floor Wall Trim Figure 3 Installation with Plywood Raft Gypsum Concrete Raft: 1" or 1" thick Finished Flooring QuietZone Acoustic Floor Mat Sub-floor Wall Trim Figure 4 Installation with Gypsum Concrete Raft

Previous Page
Next Page