Division 9 Ebook Page 153 QuietZoneŽ Acoustic Wall Framing Product Data Sheet

Product Data Sheet QuietZone Acoustic Batts Single Wood Stud Wall System STC STC Test No. Construction Description Fire Rating Fire Test 36 OCF423 Single wood studs 16" o.c.; single layer 5 /8" type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 Hr. UL U305 39 W2069 Single wood studs 16" o.c.; single layer " type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts N.A. - 40 W2469 Single wood studs 16" o.c.; double layer " type "x" gypsum drywall one side, single layer other side; one thickness, 3 " thick QuietZone Acoustic Batts N.A. - 45 W2569 Single wood studs 16" o.c.; double layer " type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 Hr. 1 UL U305 1 Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request. Single Wood Stud with Resilient Channel Wall System STC STC Test No. Construction Description Fire Rating Fire Test 46 W0769 Single wood studs, resilient channel; single layer " type "x" gypsum drywall each side; one thickness. 3 " thick QuietZone Acoustic Batts N.A. - 50 WP3230 2 Single wood studs, resilient channel; single layer 5 /8" type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 Hr. OSU T-3127 52 W0669 Single wood studs, resilient channel; single layer " type "x" gypsum drywall one side, double layer other side; one thickness, 3 " thick QuietZone Acoustic Batts N.A. - 56 W0569 Single wood studs, resilient channel; double layer " type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 Hr. 1 OSU T-3127 1 Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request. 2 Listed in the Gyspum Association Fire Resistance Design Manual Staggered Wood Stud Wall System STC STC Test No. Construction Description Fire Rating Fire Test 46 W5769 Staggered wood studs 16" o.c.; single layer 5 /8" type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 hr. 1 UL U305 51 W01486 Staggered wood studs 16" o.c.; single layer " type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts N.A. - 51 OC5FC Staggered wood studs 16" o.c.; single layer " type "x" gypsum drywall each side; two thicknesses, 3 " thick QuietZone Acoustic Batts 1 hr. OSU 4970 53 W4769 Staggered wood studs 24" o.c.; double layer " type "x" gypsum drywall one side, single layer other side; one thickness, 3 " thick QuietZone Acoustic Batts N.A. - 55 W4869 Staggered wood studs 24" o.c.; double layer " type "x" gypsum drywall each side; one thickness, 3 " thick QuietZone Acoustic Batts 1 hr. 1 UL U309 1 Rating is estimated from tests using thinner assemblies of fewer layers of gypsum drywall. Specific test references are available and will be provided upon request. QuietZone Wall Framing System STC STC Test No. Construction Description Fire Rating Fire Test 57 E90-99087 2x4 QuietZone Acoustic Framing on 16" centers, double layers " type "x" gypsum drywall each side, 3 " thick QuietZone Acoustic Batts 1 hr. 1 UL U305 60 E90-01029 2x6 QuietZone Acoustic Framing on 16" centers, double layers 5 /8" type "x" gypsum drywall each side; 5 " thick QuietZone Acoustic Batts N.A. - 63 E90-99102 2x6 QuietZone Acoustic Framing on 24" centers, double layers 5 /8" type "x" gypsum drywall each side; 5 " thick QuietZone Acoustic Batts 1 hr. OSU 4970

Previous Page
Next Page