Division 9 Ebook Page 114 Access Ceiling System

Torsion Springs must be vertical and panel in proper alignment before installing the next panel! 8. Panels must be aligned one-at-a-time as installed. Usually, aligning Saddle Clips or Spring Retainer Clips to ensure springs are in the right place and vertical will resolve alignment issues. Attempting to install all panels and then aligning as a second step will result in failure!!! Penetrations Penetrations are handled similar to most drop-ceiling applications. Use escutcheon plates where appropriate for penetrations. Avoid cutting near panel frames. 3" minimum is recommended. Independently support all suspended items including sprinklers, lights, diffusers and etceteras. Removal Cleaning Guidelines For fabric and painted finishes, general maintenance for dust removal is light brushing or vacuuming. Fingerprints and light soiling can often be removed using a dry chemical sponge or an art gum eraser. For more vigorous treatments on fabric covered panels, the fabric manufacturer should be consulted. Most polyester fabrics clean well by sponging with the foam from a mild detergent or upholstery shampoo, followed by rinsing with a clean sponge. Other cleaning agents, including solvent-based cleaners can be used to remove spotting, however always pre- test in an unseen area. ACCESS CEILING SYSTEM &'& &25325$7,21 800 Gustafson Road Ladysmith, Wisconsin 54848 T: 1-800-932-2383 F: 1-800-833-4798 www.conweddesignscape.comm Pub. No. 10018108-A. Printed in U.S.A. April 2014. 2014 Owens Corning. All Rights Reserved. INSTALLATION INSTRUCTIONS