ACCESS CEILING SYSTEM The following are guidelines given in good faith to help avoid common errors. They are not intended to be a step-by-step list of instructions or a checklist, and it is assumed the installer has general construction knowledge. Conwed Designscape Wall Technology bears no responsibility for any installation actions taken or not taken, and is not responsible for installer selection. INSPECTION Freight Damage : Inspect cartons for obvious damage before accepting and note on delivery ticket. Concealed Damage: Notify Conwed Designscape Wall Technology (1-800-932-2383) of any concealed damage within five (5) business days of receipt. Claims beyond five (5) days will be honored at the discretion of Conwed Designscape/Wall Technology or the freight company. Do not install panels of unacceptable quality. Contact your sales representative immediately. Conwed Designscape Wall Technology will not be responsible for installation or removal costs of unacceptable panels. HANDLING AND STORAGE Clean white gloves must be used whenever handling ceiling panels. Store panels on a flat, dry, solid surface. Do not store on edge. Keep panels dry, clean and free from dust and damage. SYSTEM COMPONENTS Cruciform Grid Grid Connector Perimeter Grid Spring Retainer Clip Saddle Clip Panel Pull Tool Torsion Spring Spacer Bar INSTALLATION INSTRUCTIONS