27 ENCLOSURE SOLUTIONS NFPA 285 Accepted Complete Walls Face Brick 5 8 " Type X Exterior Gypsum Sheathing Thermafiber RainBarrier 45 Mineral Wool Insulation Air Space (1" Min. - 2" Max.) 5 8 " Type X Gypsum Board Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip Fastener & 3" Washer NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier NFPA 285 Compliant Air & Water Barrier 41 Thermafiber MW, Steel Stud Jamb 43 Thermafiber MW, Steel Stud Sill Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip 5 8 " Type X Exterior Gypsum Sheathing NFPA 285 Compliant Air & Water Barrier Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Gypsum Board Galvanized Steel Studs Track Thermafiber RainBarrier 45 Mineral Wool Insulation Fastener & 3" Washer Face Brick Drip Edge Self-Supporting Through Wall Flashing Air Space (1" Min. - 2" Max.) NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 5 8 " Type X Gypsum Board Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Exterior Gypsum Sheathing NFPA 285 Compliant Air & Water Barrier Galvanized Steel Stud Track Fastener & 3" Washer Face Brick Thermafiber RainBarrier 45 Mineral Wool Insulation Air Space (1" Min. - 2" Max.) Drip Edge Self Supporting Through Wall Flashing NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 42 Thermafiber MW, Steel Stud Sill 44 Thermafiber MW, CMU Head Angle Anchor Concrete Masonry Lintel Termination Bar NFPA 285 Compliant Air & Water Barrier Air Space (1" Min. - 2" Max.) Thermafiber RainBarrier 45 Mineral Wool Insulation Face Brick Hook & Ladder Reinforcement at 16" O.C. w/ Pintle Wire Tie & RainBarrier Clip Drip Edge NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Grout Mortar Droppings Collection Device Weep Hole Insert @ 24" O.C. CMU Flashing

Previous Page
Next Page