26 Drip Edge Weep Hole Insert @ Max. 24" O.C. Galvanized Steel Stud Track Steel Shelf Angle NFPA 285 Compliant Air & Water Barrier 5 8 " Type X Gypsum Board 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Mortar Droppings Collection Device Flashing Thermafiber RainBarrier 45 Mineral Wool Insulation Termination Bar Air Space (1" Min. - 2" Max.) Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip Face Brick Fastener & 3" Washer 37 Thermafiber MW, Steel Stud Head 39 Thermafiber MW, Steel Stud Jamb Thermafiber RainBarrier 45 Mineral Wool Insulation 5 8 " Type X Gypsum Board NFPA 285 Compliant Air & Water Barrier 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip Fastener & 3" Washer Air Space (1" Min. - 2" Max.) Face Brick NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Steel Lintel Mortar Droppings Collection Device 2x Wood Blocking (Must be FRTW in Types I and II Construction) Weep Hole Insert @ Max. 24" O.C. Galvanized Steel Stud Track NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Gypsum Board Drip Edge Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip Termination Bar Thermafiber RainBarrier 45 Mineral Wool Insulation Fastener & 3" Washer Air Space (1" Min. - 2" Max.) Flashing 38 Thermafiber MW, Steel Stud Head 40 Thermafiber MW, Steel Stud Jamb Face Brick 5 8 " Type X Exterior Gypsum Sheathing Thermafiber RainBarrier 45 Mineral Wool Insulation Air Space (1" Min. - 2" Max.) Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & RainBarrier Clip 5 8 " Type X Gypsum Board Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Fastener & 3" Washer NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 2x Wood Blocking (Must be FRTW in Types I and II Construction) NFPA 285 Compliant Air & Water Barrier

Previous Page
Next Page