Division 7 Ebook Page 70 Owens Corning Enclosure Solutions NFPA 285 Design Guide

21 ENCLOSURE SOLUTIONS NFPA 285 Accepted Complete Walls 17 FOAMULAR XPS, Stucco Sill 19 FOAMULAR XPS, Steel Stud Head Owens Corning FlashSealR Foam Flashing Tape Steel Shelf Angle 5 8 " Type X Gypsum Board Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Air Space (1" Min. - 2" Max.) Air & Water Sealing Screw Fastener with Prong Washer Drip Edge Weep Hole Insert @ Max. 24" O.C. Mortar Droppings Collection Device Flashing Termination Bar Face Brick Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Owens Corning EcoTouch FIBERGLAS Batt Insulation (FS 25 Faced or Unfaced) (Optional) Owens Corning FOAMULAR 250 XPS (Max. 5") Joints Taped with Joint SealR Foam Flashing Tape Galvanized Steel Stud Track 18 FOAMULAR XPS, Steel Stud Head 20 FOAMULAR XPS, Steel Stud Jamb Owens Corning Thermafiber Safing Insulation (Min. 4", 25% Min. Compression) 5 8 " Type X Gypsum Board Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Air & Water Sealing Screw Fastener with Prong Washer Air Space (1" Min. - 2" Max.) Face Brick Owens Corning FlashSealR Foam Flashing Tape Owens Corning EcoTouch FIBERGLAS Batt Insulation (FS 25 Faced or Unfaced) (Optional) Owens Corning FOAMULAR 250 XPS (Max. 5") Joints Taped with Joint SealR Foam Flashing Tape Steel Lintel Mortar Droppings Collection Device 2x Wood Blocking (Must be FRTW in Types I and II Construction) Weep Hole Insert @ Max. 24" O.C. Galvanized Steel Stud Track Flashing Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Gypsum Board Drip Edge Termination Bar Air Space (1" Min. - 2" Max.) Air & Water Sealing Screw Fastener with Prong Washer Owens Corning FlashSealR Foam Flashing Tape Owens Corning EcoTouch FIBERGLAS Batt Insulation (FS 25 Faced or Unfaced) (Optional) Owens Corning FOAMULAR 250 XPS (Max. 3") Joints Taped with Joint SealR Foam Flashing Tape Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer 5 8 " Type X Gypsum Board Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Exterior Gypsum Sheathing Sealant NFPA 285 Compliant Air & Water Barrier Stucco Assembly ( 7 8 " Min.) Owens Corning FOAMULAR 250 XPS (Max. 5") Air & Water Sealing Screw Fastener with Prong Washer Drip Edge Self Supporting Sill Pan Flashing NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Sealant Galvanized Steel Stud Track Sealant

Previous Page
Next Page