Division 7 Ebook Page 67 Owens Corning Enclosure Solutions NFPA 285 Design Guide

18 5 FOAMULAR XPS, Steel Stud Jamb 7 FOAMULAR XPS, Steel Stud Sill 5 8 " Type X Gypsum Board Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Exterior Gypsum Sheathing NFPA 285 Compliant Air & Water Barrier Galvanized Steel Stud Track Air & Water Sealing Screw Fastener with Prong Washer Face Brick Owens Corning FOAMULAR 250 XPS (Max. 3") Air Space (1" Min. - 2" Max.) Drip Edge Self Supporting Through Wall Flashing NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Owens Corning Thermafiber Safing Insulation (Min. 4", 25% Min. Compression) 6 FOAMULAR XPS, Steel Stud Sill 8 FOAMULAR XPS, CMU Head Angle Anchor Concrete Masonry Lintel Termination Bar NFPA 285 Compliant Air & Water Barrier Air Space (1" Min. - 2" Max.) Owens Corning FOAMULAR CW25 XPS (Max. 5") Face Brick Hook & Ladder Joint Reinforcement at 16" O.C. w/ Pintle Wire Tie Drip Edge NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Grout Mortar Droppings Collection Device Weep Hole Insert @ 24" O.C. CMU Flashing Face Brick 5 8 " Type X Exterior Gypsum Sheathing Owens Corning FOAMULAR 250 XPS (Max. 5") Air Space (1" Min. - 2" Max.) 5 8 " Type X Gypsum Board NFPA 285 Compliant Air & Water Barrier Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Air & Water Sealing Screw Fastener with Prong Washer NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer 5 8 " Type X Exterior Gypsum Sheathing NFPA 285 Compliant Air & Water Barrier Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Gypsum Board Galvanized Steel Studs Track Owens Corning FOAMULAR 250 XPS (Max. 5") Air & Water Sealing Screw Fastener with Prong Washer Face Brick Drip Edge Self-Supporting Through Wall Flashing Air Space (1" Min. - 2" Max.) NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier

Previous Page
Next Page