Division 7 Ebook Page 66 Owens Corning Enclosure Solutions NFPA 285 Design Guide

17 ENCLOSURE SOLUTIONS NFPA 285 Accepted Complete Walls 1 FOAMULAR XPS, Steel Stud Head 3 FOAMULAR XPS, Steel Stud Jamb Steel Lintel Mortar Droppings Collection Device 2x Wood Blocking (Must be FRTW in Types I and II Construction) Weep Hole Insert @ Max. 24" O.C. Galvanized Steel Stud Track Flashing NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. 5 8 " Type X Gypsum Board Drip Edge Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Termination Bar Owens Corning FOAMULAR 250 XPS (3" Max.) Air Space (1" Min. - 2" Max.) Air & Water Sealing Screw Fastener with Prong Washer 2 FOAMULAR XPS, Steel Stud Head 4 FOAMULAR XPS, Steel Stud Jamb Face Brick 5 8 " Type X Exterior Gypsum Sheathing Owens Corning FOAMULAR 250 XPS (3" Max.) Air Space (1" Min. - 2" Max.) Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer NFPA 285 Compliant Air & Water Barrier 5 8 " Type X Gypsum Board Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Air & Water Sealing Screw Fastener with Prong Washer NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier 2x Wood Blocking (Must be FRTW in Types I and II Construction) Owens Corning Thermafiber Safing Insulation (Min. 4", 25% Min. Compression) Owens Corning FOAMULAR 250 XPS (5" Max.) 5 8 " Type X Gypsum Board NFPA 285 Compliant Air & Water Barrier 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer Air & Water Sealing Screw Fastener with Prong Washer Air Space (1" Min. - 2" Max.) Face Brick NFPA 285 Compliant Air & Water Barrier- Wrap into Rough Opening and Tie into Window or Door Assembly Per Manufacturer's Instructions to Create Continuous Air & Water Barrier Drip Edge Weep Hole Insert @ Max. 24" O.C. Galvanized Steel Stud Track Steel Shelf Angle NFPA 285 Compliant Air & Water Barrier 5 8 " Type X Gypsum Board 5 8 " Type X Exterior Gypsum Sheathing Owens Corning EcoTouch FIBERGLAS Batt Insulation (Optional) (FS 25 Faced or Unfaced) Min. 3 1 2 " 18 Ga. Galvanized Steel Studs @ 24" O.C. Max. Mortar Droppings Collection Device Flashing Owens Corning FOAMULAR 250 XPS (5" Max.) Termination Bar Air Space (1" Min. - 2" Max.) Air & Water Sealing Screw Fastener with Prong Washer Face Brick Barrel Screw Masonry Anchor w/ Thermal Break Clip, Pintle Wire Tie, & Air & Water Sealing Washer

Previous Page
Next Page