Division 7 Ebook Page 569 Steel Stud Air Leakage and Water Resistance ASTM E2357 and ASTM E331 Tech Bulletin

Technical Bulletin SS-03 ENCLOSURE SOLUTIONS Technical Bulletin SS-02 Pub. No. 10020913. Printed in U.S.A. May 2016. THE PINK PANTHER & 1964-2016 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2016 Owens Corning. All Rights Reserved. Thermafiber, Inc. All Rights Reserved. Trademarks are the properties of their respective owners. OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-438-7465 1-800-GET-PINK owenscorning.com/enclosure Deformation Loading Sequence Table 1 Test # Cycles/Period Pressure Result Deformation 1/60 minutes +600 Pa (+12.54 psf) No Damage Deformation 1/60 minutes -600 Pa (-12.54 psf) No Damage Cyclic Loading 2000/5 seconds (1000 each, infiltration & exfiltration) +/- 800 Pa (+/- 16.72 psf) No Damage Gust Loading 2/3 seconds (1 each, infiltration & exfiltration) +/- 1200 Pa (+/- 25.06 psf) No Damage ASTM E2357, Air Leakage Rate After Loading Sequence (cfm/ft 2 ) Table 2 Tested at 75 pa (1.57 psf) Air Infiltration Air Exfiltration ASHRAE 90.1 and ABAA Air Barrier Criteria Qualifies as an Air Barrier Assembly Opaque Wall 0.0003 0.0002 0.04 maximum Yes Penetrated Wall 0.0005 0.0006 0.04 maximum Yes