Division 7 Ebook Page 562 Steel Stud Energy Codes and Standards Tech Bulletin

Technical Bulletin SS-01 ENCLOSURE SOLUTIONS Prescriptive R (minimum) Requirements for Steel Framed Walls, Above Grade Zone ASHRAE 90.1 - 2004 ASHRAE 90.1 - 2007 and 2010 ASHRAE 90.1 - 2013 IECC - 2012 IECC - 2015 ASHRAE 189.1 - 2011 (alternate to IgCC - 2012)* ASHRAE 189.1 - 2011 (alternate to IgCC - 2015)* Non- Residential Non- Residential Non- Residential Non- Residential Non- Residential Non- Residential Non- Residential 1 13 13 + 5.0 13 + 5.0 13 + 5.0 13 + 5.0 13 + 5.0 13 + 5.0 13 2 13 13 + 7.5 13 + 3.8 13 + 7.5 13 + 5.0 13 + 7.5 13 + 5.0 13 + 7.5 13 + 5.0 13 + 10.0 13 + 3.8 13 + 7.5 3 13 13 + 3.8 13 + 3.8 13 + 7.5 13 + 5.0 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 5.0 13 + 10.0 13 + 5.0 13 + 7.5 4 13 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 10.0 13 + 10.0 13 + 12.5 13 + 12.5 5 13 + 3.8 13 + 7.5 13 + 7.5 13 + 7.5 13 + 10.0 13 + 10.0 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 10.0 13 + 10.0 13 + 12.5 13 + 12.5 6 13 + 3.8 13 + 7.5 13 + 7.5 13 + 7.5 13 + 12.5 13 + 12.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 7.5 13 + 10.0 13 + 10.0 13 + 15.6 13 + 15.6 7 13 + 7.5 13 + 7.5 13 + 7.5 13 + 15.6 13 + 12.5 13 + 15.6 13 + 7.5 13 + 15.6 13 + 7.5 13 + 15.6 13 + 10.0 13 + 18.8 13 + 15.6 13 + 18.8 8 13 + 7.5 13 + 10.0 13 + 7.5 13 + 18.8 13 + 18.8 13 + 18.8 13 + 7.5 13 + 17.5 13 + 7.5 13 + 17.5 13 + 10.0 13 + 21.9 13 + 25 13 + 25 *Section 605.1.1 of the IgCC-2012, regarding "Building Envelope Systems, Prescriptive Compliance", states that when the IgCC is used, the building thermal envelope R shall exceed the requirements of the IECC by not less than 10%. EcoTouch Flame Spread 25 Insulation, with facer FOAMULAR 250 XPS Insulation EcoTouch PINK Fiberglass Insulation, unfaced

Previous Page
Next Page