Division 7 Ebook Page 549 UL Evaluation Report

Page 2 of 13 2. SCOPE OF EVALUATION: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Code (IECC) ICC-ES Acceptance Criteria for Foam Plastic Insulation (AC12), dated June 2012 ICC-ES Acceptance Criteria for Foam Plastic Sheathing Panels used as Water Resistive Barriers (AC71), dated February 2003 ICC-ES Acceptance Criteria for Quality Documentation (AC10), dated December 2012 The FOAMULAR XPS Insulation boards were evaluated for the following properties (Also see Table 1a): Surface Burning Characteristics (ANSI/UL723, ASTM E84) Thermal and Physical Properties (ASTM C578) Roofing Systems for Exterior Fire Exposure (ANSI/UL790, ASTM E108) Roof Deck Construction Material With Resistance to Internal Fire Exposure (ANSI/UL1256) Fire-resistance-rated construction (ANSI/UL263, ASTM E119) For Use in Attics and Crawl Spaces (AC12, App. A and B) For Use Without a Thermal Barrier - Special Approval (NFPA 286) Water-resistive Barrier (AC71) For Use on Exterior Commercial Walls (NFPA 285)