Division 7 Ebook Page 503 EuroSpan Acoustical Wall System, 09 84 14

Eurospan Translucence System 3.1.1.2 INSTALLATION: A. Install stainless steel Cable fittings in accordance with manufacturer's instructions, and to structure that is capable of maintaining the load required to install the fabric correctly. Coordinate all cable mounting points with the general contractor. 1. Other fasteners may be used as may be required for specific substrates, providing they are in strict accordance with the manufacturer's instructions and comply with the general contractor requirements. B. Stretch the fabric and secure into the cable fittings so that it will be smooth, free of wrinkles or puckers. Adjust fabric to meet the required dimensional layout. Tolerance: +- 3" of detailed layout. Secure anchoring system to building structure. C. Examine fabric as it is installed for damage, imperfections, and soiling. Notify other trades to use care in working around the installed fabric so as not to soil or damage the surface. 3.1.1.3 CLEANING AND PROTECTION A. Clean exposed surfaces of ceiling surface as necessary, complying with manufacturer's instructions for cleaning and repair of minor finish damage. Remove and replace work that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage. B. Protect the installed work as recommended by the manufacturer, so that the work will be without damage and deterioration at the time of acceptance by the Owner. END OF SECTION Pub No 10019383 2014 Owens Corning. All Rights Reserved. STRETCHED FABRIC CEILING SYSTEMS 09 54 43 - 3