Division 7 Ebook Page 501 EuroSpan Acoustical Wall System, 09 84 14

Eurospan Translucence System PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the engineer. Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise. SECTION 09 54 43 STRETCHED FABRIC CEILING SYSTEMS PART 1 - GENERAL 1.1.1.1 SUMMARY A. Section Includes: Provide field installed Eurospan Translucence Stretch Fabric System, consisting of a multi direction factory sewn fabric, suspended through stretching via stainless steel cables and fittings. This is a frameless system commonly installed as visual ceiling and wall elements. 1.1.1.2 SUBMITTALS: A. Product Data: Submit product characteristics, performance criteria, and limitations, including installation instructions, for each type of product indicated. B. Shop Drawings: Show typical reflected ceiling plans, sections, and details. C. Samples: Provide 12" by 12" samples of fabric with factory detailed edge, and representative samples of each type of mounting device. D. Certified Test Reports: 1. Fire Performance: Submit test data from an independent testing agency, acceptable to authorities having jurisdiction, indicating that system components comply with requirements indicated for fire performance. 1.1.1.3 QUALITY ASSURANCE: A. Installer Qualifications: The installation work of this Section shall be performed by an experienced installation contractor approved and certified by the manufacturer. B. Fire Hazard Classification: ASTM E84, NFPA Class A / UBC Class I. 1.1.1.4 DELIVERY, STORAGE AND HANDLING: A. Deliver, store, and protect materials in accordance with manufacturer's instructions. Store in a dry indoors location. Protect materials from moisture and soiling. STRETCHED FABRIC CEILING SYSTEMS 09 54 43 - 1

Previous Page
Next Page