Division 7 Ebook Page 489 EuroSpan Translucence System, 09 54 43

Eurospan Acoustical Wall System PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the engineer. Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise. SECTION 09 84 14 ACOUSTIC STRETCHED FABRIC WALL SYSTEMS PART 1 - GENERAL 1.1.1.1 SUMMARY A. Section Includes: Provide field installed Eurospan Acoustical Wall System, consisting of a commercial grade panel or upholstery fabric applied over an acoustical core, attached to a continuous mounting system of rigid extrusions. 1.1.1.2 SUBMITTALS A. Product Data: Submit product characteristics, performance criteria, and limitations, including installation instructions, for each type of product indicated. B. Shop Drawings: Show typical wall elevations, sections, and details. C. Samples: Provide 12" by 12" samples of fabric, and representative samples of each type of rigid mounting devices. D. Certified Test Reports: 1. Fire Performance: Submit test data from an independent testing agency, acceptable to authorities having jurisdiction, indicating that system components comply with requirements indicated for fire performance. 2. Acoustical Performance: Submit test data from independent testing agencies showing that system complies with the specified requirements for acoustical performance. 1.1.1.3 QUALITY ASSURANCE A. Installer Qualifications: The installation work of this Section shall be performed by an experienced installation contractor approved and certified by the manufacturer. B. Fire Hazard Classification: ASTM E84, NFPA Class A / UBC Class I. C. Noise Reduction Coefficient (NRC): ASTM C423. ACOUSTIC STRETCHED FABRIC WALL SYSTEMS 09 84 14 - 1

Previous Page
Next Page