4. Roof Verify that all roof flashings have been installed in accordance with the guidelines set by the Asphalt Roofing Manufacturers Association (ARMA). 5. Kick-out flashing Kick-out flashing must be installed where required. The kick-out flashing must be leak-proof and angled (min 100) to allow for proper drainage and water diversion. C. Do not proceed until all unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Protect all surrounding areas and surfaces from damage and staining during application of Senergy Sentry Stucco CI Wall System. B. Protect finished work at end of each day to prevent water penetration. 3.03 MIXING General: No additives are permitted unless specified in product mixing instructions. Close containers when not in use. Prepare in a container that is clean and free of foreign substances. Do not use a container which has contained or been cleaned with a petroleum-based product. Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically. NOTE TO SPECIFIER: Keep only the products in this section which will be incorporated in the Sentry Stucco CI System. Delete those not to be utilized. [A. Air/Water Resistive Barrier 1. SENERSHIELD-R Mix SENERSHIELD-R with a clean, rust-free paddle and drill until thoroughly blended. Do not add water.] B. SENERTHIK Base Coat: 1. Use mixer that is clean and free of foreign substances. 2. Mix one bag (42.64 kb/94 lbs.) Portland cement, 68-90.7 kg (150-200 lbs.) silica sand, and one package (.45 kg/1lb.) FIBERFILL with SENERTHIK BASE LIQUID (18.1 kg/40 lbs.) Mix for three to five minutes to a homogeneous consistency. 3. Clean, potable water may be added to adjust workability. [C. Adhesive/Base Coat for EPS insulation architectural features 1. Senergy ALPHA Base Coat: a. Prepare in a container which is clean and free of foreign substances. Do not use container which has contained or been cleaned with a petroleum-based product. b. Mix Base Coat with a clean, rust-free paddle and drill until thoroughly blended, before adding Portland cement. c. Mix one part (by weight) Portland cement with one part Base Coat. Add Portland cement in small increments, mixing until thoroughly blended after each additional increment. d. Clean, potable water may be added to adjust workability 2. ALPHA DRY Base Coat: a. Mix and prepare each bag in a 19-liter (5-gallon) pail which is clean and free of foreign substances. Do not use a container which has contained or been cleaned with a petroleum-based product. b. Fill the container with approximately 5.6 liters (1 1/2 gallons) of clean, potable water. c. Add ALPHA DRY Base Coat in small increments, mixing after each additional increment. d. Mix ALPHA DRY Base Coat and water with a clean, rust-free paddle and drill until thoroughly blended. e. Additional ALPHA DRY Base Coat or water may be added to adjust workability.] D. SENERGY FINISH [SENERFLEX] [SILCOAT ] [SENERLASTIC ] [TINTED PRIMER] and [ANTICOGLAZE] 1. Thoroughly mix the factory-prepared material with a clean paddle and drill until thoroughly blended. 2. A small amount of clean, potable water may be added to adjust workability. 3. Additives are not permitted. 4. Close container when not in use. 5. Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically. E. SENERGY [AURORA TC-100], [BOREALIS], [AURORA STONE] and [ALUMINA] SPECIALTY FINISH COATS 1. Gently mix the contents of the pail for 1 minute using a low RPM 1/2 inch drill equipped with a mixing paddle such as a Demand Twister or a Windlock B-MEW, B-M1 or B-M9. 2. Additives are not permitted. 3. Close container when not in use. 4. Clean tools and equipment with water immediately after use. Dried material can only be removed mechanically. 3.04 APPLICATION General: Apply Sentry Stucco CI System materials in accordance with BASF Wall System Specifications. NOTE TO SPECIFIER: Keep only the products in this section which will be incorporated in the Sentry Stucco CI System. Delete those not to be utilized. [A. SENERSHIELD-R 1. All sheathing joints and windows/openings must be protected and the SENERSHIELD-R Air/Water Resistive barrier applied in accordance with Senergy's Secondary Moisture Protection Barrier Guidelines

Previous Page
Next Page