Division 7 Ebook Page 482 Senergy Sentry Stucco Wall System, 07 24 16

G. Section 07 27 00 Air barriers H. Section 07 62 00 Sheet metal flashing and trim I. Section 07 65 00 Flexible flashing J. Section 07 90 00 Joint protection K. Section 08 00 00 Openings L. Section 09 22 00 Supports for plaster and gypsum board M. Section 09 22 16 Non-structural metal framing N. Section 09 29 00 Gypsum board 1.04 REFERENCES A. ASTM A653 / A653M Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process B. ASTM B69 Standard Specification for Rolled Zinc C. ASTM C79/C79M-04a Standard Specification for Gypsum Sheathing Board D. ASTM C150 Standard Specification for Portland cement E. ASTM C578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation F. ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster G. ASTM C1135 Standard Test Method for Determining Tensile Adhesion Properties of Structural Sealants H. ASTM C1177 Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing I. ASTM C1325 Standard Specification for Non-Asbestos Fiber-Mat Reinforced Cementitious Backer Units J. ASTM C1396 / C1396M - 09a Standard Specification for Gypsum Board K. ASTM D226 Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing L. ASTM D1784 Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (PVC) Compounds M. ICC-ES AC11 Cementitious Exterior Wall Coatings N. ESR-1794 ICC Evaluation Service, Inc., ES Report 1.05 SUBMITTALS A. Submit under provisions of Section [01 33 00] B. Product Data: Provide data on Sentry Stucco CI System materials, product characteristics, performance criteria, limitations and durability. C. Code Compliance: Provide manufacturer's applicable code compliance report. D. Samples: Submit [two] [ x ] [millimeter] [inch] size samples of Sentry Stucco CI System design illustrating Finish Coat color and texture range. E. Certificate: System manufacturer's approval of applicator. F. Sealant: Sealant manufacturer's certificate of compliance with ASTM C1135. G. System manufacturer's current specifications, typical details, system design guide and related product literature which indicate preparation required, storage, installation techniques, jointing requirements and finishing techniques. 1.06 QUALITY ASSURANCE A. Manufacturer: More than 10 years in the insulated exterior wall systems industry. B. Applicator: Approved by BASF Construction Chemicals, LLC - Wall Systems (hereinafter referred to as BASF Wall Systems) in performing work of this section. C. Regulatory Requirements: Conform to applicable code requirements. D. Field Samples 1. Provide under provisions of Section [01 43 36] [01 43 39]. 2. Construct one field sample panel for each color and texture, [ x ] [meters] [feet] in size of system materials illustrating method of attachment, surface Finish color and texture. 3. Prepare each sample panel using the same tools and techniques to be used for the actual application. 4. Locate sample panel where directed. 5. Accepted sample panel [may] [may not] remain as part of the work. 6. Field samples shall be comprised of all wall assembly components including substrate, water-resistive barrier, plaster trim accessories, Base Coat, Reinforcing Mesh, primer, Finish Coat and typical sealant/flashing conditions. 1.07 DELIVERY, STORAGE AND HANDLING A. Deliver, store and handle products under provisions of Section [01 65 00] [01 66 00] [ ]. B. Deliver Sentry Stucco CI System materials in original unopened packages with manufacturer's labels intact. C. Protect Sentry Stucco CI System materials during transportation and installation to avoid physical damage. D. Store Sentry Stucco CI System materials in cool, dry place protected from exposure to moisture and freezing. E. Store at no less than 4C/40F (10C/50F for AURORA STONE, AURORA TC-100, ALUMINA and BOREALIS Finish). F. Store FIBERLATH Reinforcing Mesh in cool, dry place protected from exposure to moisture. G. Store insulation boards flat and protected from direct sunlight and extreme heat. 1.08 PROJECT/SITE CONDITIONS A. Do not apply Sentry Stucco CI System materials in ambient temperatures below 4C/40F (10C/50F for AURORA STONE, AURORA TC-100, ALUMINA and BOREALIS Finish).

Previous Page
Next Page