Division 7 Ebook Page 413 ELAMINATOR Insulation System, 07 21 16

OptiLiner Banded Liner System, Thermal, Metal Building PART 2 - PRODUCTS 2.1.1.1 MANUFACTURER A. Owens Corning Insulating Systems, LLC, Toledo, OH 43659; www.owenscorning.com. 2.1.1.2 MATERIALS Note: Owens Corning shall approve all materials used in the OptiLiner Banded Liner System. Contact Owens Corning for specific materials approved for use within the OptiLiner Banded Liner System. A. The OptiLiner System consists of the following materials: 1. Unfaced light density fiberglass metal building insulation in the one of the following product categories: a. Owens Corning Certified R Metal Building Insulation 1) Complies with ASTM C991 Type 1. 2) Complies with NAIMA 202-96-REV 2000. 3) Flame Spread Index <25 and Smoke Developed Index <50 when tested in accordance with ASTM E84, NFPA 255 and UL 723. 4) Certified by SCS Global Services to contain a minimum of 65% recycled glass content, 18% pre-consumer and 47% post-consumer. 5) Thermal Resistance: Available R-Values = R10, R11, R13, R16, R19, R25 or R30. 6) Unfaced. 7) GREENGUARD Indoor Air Quality Certified . 8) GREENGUARD Gold Certified. b. Owens Corning MBI Plus Metal Building Insulation 1) Flame Spread Index <25 and Smoke Developed Index <50 when tested in accordance with ASTM E 84, NFPA 255 and UL 723. 2) Certified by SCS Global Services to contain a minimum of 65% recycled glass content, 18% pre-consumer and 47% post-consumer. 3) Thermal Resistance: Available R-Values = R10, R11, R13, R16, R19, R25 or R30. 4) Unfaced. 5) GREENGUARD Indoor Air Quality Certified . 6) GREENGUARD Gold Certified. c. Owens Corning Metal Building Utility Blanket 1) Flame Spread Index <25 and Smoke Developed Index <50 when tested in accordance with ASTM E 84, NFPA 255 and UL 723. 2) Certified by SCS Global Services to contain a minimum of 65% recycled glass content, 18% pre-consumer and 47% post-consumer. 3) Thermal Resistance: Available R-Values = R7. 4) Unfaced. 5) GREENGUARD Indoor Air Quality Certified . 6) GREENGUARD Gold Certified. 2. Fabric liner facing/vapor barrier composed of woven high-density polyethylene coated on both sides with polyethylene. Complies with the following: a. ASTM C1136, Types I through Type VI 1) Type I-IV exception for dimensional stability (value is < 2.0%.) b. Perm rating: "d0.02 when tested in accordance with ASTM E 96 Procedure A. c. Flame Spread Index < 25 and Smoke Developed Index < 50 when tested in accordance with ASTM E 84. d. Color: 1) White 2) Black 3. Vapor barrier adhesive. Complies with the following: a. Application temperature 10F to 110 F PRE-ENGINEERED BUILDING BLANKET INSULATION 07 21 16 - 3

Previous Page
Next Page