Fiberglas, Exterior Wall Thermal Insulation B. Insulation, at Metal Framing: Note to Specifier: Select from the following table: Thickness Width Length R-value (per ASTM C 518) 3"89mm 16" 406mm - 24" 609mm 96" 2438mm 11.0 3"89mm 16" 406mm - 24" 609mm 96" 2438mm 13.0 6"159m m 16" 406mm - 24" 609mm 96" 2438mm 19.0 C. Insulation, at Wood Framing: Note to Specifier: Select from the following table: Thickness Width Length R- value (per ASTM C 518) 3"89mm 15" 381mm - 23" 584mm 93" 2362mm 11.0 3"89mm 15" 381mm - 23" 584mm 93" 2362mm 13.0 6"159m m 15" 381mm - 23" 584mm 93" 2362mm 19.0 D. Special Application Insulation: Note to Specifier: Select from the following table: Thickness Width Length R- value (per ASTM C 518) 9"241m m 16" 406mm - 24" 609mm 48" 1219mm 30.0 6"159m m 48" 1219mm 40'12.19m 19.0 3"89mm 48" 1219mm 72'21.95m 11.0 E. Vapor Retarder Perm Rating: ASTM E 96. 1. FRK facing Perms Maximum 0.10 2. PSK facing Perms Maximum 0.10 F. Surface Burning Characteristics for FRK and PSK faced product: ASTM E 84. 1. Maximum flame spread: 25, 2. Maximum smoke developed: 50. G. Combustion Characteristics: Classified non-combustible by model building codes. Not required to be covered. May be left exposed. H. Dimensional Stability: Linear shrinkage less than 0.1% 2.1.1.5 THERMAL BATT INSULATION A. Type: Unfaced glass fiber thermal insulation complying with ASTM C 665, Type I and ASTM E 136. B. Type: Kraft faced glass fiber insulation complying with ASTM C 665, Type II, Class C. C. Type: Foil faced glass fiber thermal insulation complying with ASTM C 665, Type III, Class B and C. THERMAL BLANKET INSULATION 07 21 16 - 5