Division 7 Ebook Page 397 EcoTouch FIBERGLAS Insulation, 07 21 16

Fiberglas, Exterior Wall Thermal Insulation Type Flame Spread Smoke Developed 701 Unfaced 20 711 Unfaced 20 703 Unfaced 15 0 703 ASJ-faced 25 50 703 FRK-faced 25 50 705 Unfaced 15 0 705 ASJ-faced 25 50 705 FRK-faced 25 50 G. Noise Reduction Coefficient: ASTM C 423 on a Type A mounting. Note to Specifier: Select from the following table: Type Thickness NRC Type701/711 Un- faced 1" 25mm 0.70 2" 51mm 0.90 3" 76mm 1.15 Type 703 Unfaced 1" 25mm 0.70 2" 51mm 1.00 3" 76mm 1.10 Type 705 Unfaced 1" 25mm 0.65 2" 51mm 0.95 3" 76mm 1.10 Type 703 FRK- faced 1" 25mm 0.65 2" 51mm 0.75 Type705 FRK- faced 1" 25mm 0.55 2" 51mm 0.60 Type 703 ASJ- faced 1" 25mm 0.65 2" 51mm 0.75 Type 705 ASJ- faced 1" 25mm 0.50 2" 51mm 0.65 H. Dimensional Stability: Linear shrinkage less than 0.1% 2.1.1.4 FLAME SPREAD 25 INSULATION A. Type: FRK (foil) and PSK (white) faced glass fiber thermal insulation complying with ASTM C 665, Type III for FRK (foil) and Type II for PSK (white), Class A. THERMAL BLANKET INSULATION 07 21 16 - 4