Division 7 Ebook Page 393 FOAMULAR Insulation, Masonry Cavity Wall, 07 21 13

FOAMULAR Insulation, Thermal, Masonry Cavity Wall Note to Specifier: Optional and additional adhesive instructions, edit, combine and/or retain as needed. 1. Spot Method: Apply 4 spots of adhesive per insulation board and set insulation firmly against the inside wythe of masonry or other construction as shown. Apply spots at each corner; spread spots to form pads 4 inches (101 mm) in diameter by 1/4 inch (6 mm) thick. 2. Serrated-Trowel Method: Apply adhesive to entire surface of each insulation board with a serrated trowel complying with the adhesive manufacturer's written instructions. 3. Seal joints between foam plastic insulation units by applying adhesive, mastic, or sealant to edges of each board to form a tight seal as units are pressed into place. Fill voids in completed installation with adhesive, mastic, or sealant. 4. Supplement adhesive attachment of insulation by securing boards with two-piece wall ties designed for this purpose and specified in Division 04 - Masonry. END OF SECTION Pub No 10019376 2014 Owens Corning. All Rights Reserved. FOAM BOARD INSULATION 07 21 13 - 4