Division 7 Ebook Page 325 ELAMINATOR® Insulation System Product Data Sheet

Product Data Sheet ELAMINATOR Insulation System (1) Two-Layer The ELAMINATOR system and machines shall be used to install the first layer of Owens Corning faced EcoTouch Insulation for Certified R Metal Building, parallel to and between the purlins or EcoTouch Insulation for MBI Plus. The insulation shall have an R-value of _____ and be faced or be applied unfaced over a facing with permeance rating not greater than _____ perm as tested in accordance with ASTM E96. The materials shall have a Flame Spread rating of 25 or less and a Smoke Developed rating of 50 or less as tested in accordance with UL 723, ASTM E84, or NFPA 255. The EcoTouch Certified R Metal Building insulation shall be marked on the unfaced side with NAIMA 202-9 identification, R-value, and manufacturer identification (OCF). The insulation or facing shall be pulled taut and held in position with the ELAMINATOR machines while being secured only at the end wall rafters with double-sided adhesive tape. Facing tabs shall be overlapped over the purlins as the ELAMINATOR machines are advanced, to ensure proper alignment and facing overlap, and vapor retarder integrity. The second layer, of Owens Corning unfaced EcoTouch Insulation for MBI Plus or EcoTouch Insulation for Certified R Metal Building, shall be installed manually across the purlins, parallel with the roof sheets without gaps or voids. Insulation shall be Owens Corning unfaced EcoTouch Insulation for MBI Plus or EcoTouch Insulation for Certified R Metal Building having an R-value of ______. One-inch thermal spacer blocks 2 are installed after all Fiberglass metal building insulation is in place. Thermal spacer blocks 2 must be installed with standing seam roofs to meet stated U-values. (2) Single-Layer The ELAMINATOR system and machines shall be used to install the vapor retarder facing ahead of and separately from the insulation, parallel to the purlins. The vapor retarder facing shall have a permeance rating of not greater than _____ perm as tested in accordance with ASTM E96. It shall have a Flame Spread rating of 25 or less and a Smoke Developed rating of 50 or less as tested in accordance with UL 723, ASTM E84, or NEPA 255. The facing shall be pulled taut and held in position with the ELAMINATOR machines after being secured to the end wall rafters with double-sided adhesive tape. Facing tabs shall be overlapped on top of purlins, as the ELAMINATOR machines are advanced, to ensure proper alignment and overlapping of the facing, and vapor retarder integrity. Unfaced insulation shall be installed manually across the purlins, or perpendicular with thermal blocks, on top of the facing and parallel to the roof sheets. The insulation shall be Owens Corning unfaced 2 Recommended 1" thick FOAMULAR 250 PINK Extruded Polystyrene (XPS) Insulation. EcoTouch Insulation for MBI Plus not to be laminated. EcoTouch Insulation for MBI Plus or EcoTouch Insulation for Certified R Metal Building having an R-value of _____. It shall be installed so there are no gaps or voids. It shall have a Flame Spread rating of 25 or less and a Smoke Developed rating of 50 or less as tested in accordance with UL 723, ASTM E84, or NFPA 255. One-inch thermal spacer blocks* are required with standing seam roofs to meet stated U-values.

Previous Page
Next Page