Division 7 Ebook Page 323 ELAMINATOR® Insulation System Product Data Sheet

Product Data Sheet ELAMINATOR Insulation System Installation Method Double Layer Single Layer 100 Series 300 Series Product Required EcoTouch Insulation for Certified R Metal Building with PureFiber Technology Faced R-10 R-11 R-13 R-16 R-19 R-25 R-30 EcoTouch Insulation for MBI Plus with PureFiber Technology Unfaced R-10 R-11 R-13 R-16 R-19 R-25 R-30 Facing _________________________ (see attached data sheet) Description The Owens Corning ELAMINATOR Insulation System utilizes two series of machines designed to travel along the purlins dispensing faced insulation or facing from rolls: 100 Series and 300 Series. Both control the tension applied to the rolls as they are dispensed and correctly position the facing with respect to the purlins so that installed insulation is consistent and fully expanded. The 300 Series machines are designed to meet OSHA regulations for low-slope roofs, no more than 3:12 slope. To use the machines, the top flange of the purlin or bar joist structure, must withstand 200 lbs. with minimum deflection. Owens Corning believes the ELAMINATOR 300 Series machines, if operated according to written instructions, comply with 29 CFR, 1926.501 (b)(10), with the roofing contractor providing a warning line system and 100% personal fall protection for his workers outside the warning line system. The 300 Series machines provide a guardrail system and complete the warning line system. It is the responsibility of the ELAMINATOR licensee and the roofing contractor to comply with all OSHA fall protection standards. The 100 Series machines require 100% personal fall protection for the ELAMINATOR installers or use with Sky-Web II , slopes up to 3:12. 100 Series has two machines: 100 and 120. The ELAMINATOR Insulation System offers a choice of installation methods: (1) Two-Layer with faced Owens Corning EcoTouch Insulation for Certified R Metal Building or unfaced EcoTouch Insulation for MBI Plus between the purlins using the 100 machines which install the faced insulation parallel to the purlins or the 120 machines to install patented folded facing with pieces of EcoTouch Insulation for MBI Plus. Unfaced EcoTouch Insulation for MBI Plus or EcoTouch Insulation for Certified R Metal Building is installed as a second layer over the first in the insulation layer and purlins, parallel to the roof sheets. Figure 1 100 Series - 100 Machines Figure 2 100 Series - 120 Machines Figure 3 300 Series CERTIFIED ELAMINATOR OWENS CORNING OPERATOR PROGRAM

Previous Page
Next Page