Division 7 Ebook Page 321 OptiLinerí Banded Liner System Product Data Sheet

Product Data Sheet OptiLiner Banded Liner System Meets Model Fire Code Ratings Both the fabric and insulation materials have a flame spread rating of 25 or less and a smoke developed rating of 50 or less. This usually means that the products will be granted immediate building code approval. Bright and Resilient Interior Finish The OptiLiner white fabric is stronger than traditional facings used in metal buildings. The bright white color has a light reflectance rating of greater than 80%, which may allow for reduced lighting loads in the design space. GREENGUARD Certified All Owens Corning EcoTouch Insulation for Metal Building products are certified to meet indoor air quality standards under the GREENGUARD Certification Program and the GREENGUARD Gold Certification Program. Cleanable Facing A soft cloth with soap and water or non-abrasive household cleaner can be used to clean the facing. Solvent-based cleaners and abrasive pads should be avoided. Application Recommendations OptiLiner Roof System- WORKERS MUST USE OSHA REQUIRED FALL PROTECTION WHEN INSTALLING THE BANDED LINER SYSTEM AT HEIGHTS. (SEE OSHA REGULATIONS AT 29 CFR 1926, SUBPART M). Proper safety measures should be taken when installing the OptiLiner roof system. An installing contractor should employ a site specific fall protection plan. Detailed roof and wall application recommendations can be found in the roof and wall installation guides for the OptiLiner system. Technical Data-Insulation 2 Fire Resistance ASTM E84, UL 723 or NFPA 255 Test Methods for Surface Burning Characteristics of Building Materials 3 - Max Flame Spread Index 25; Max Smoke Developed Index 50 2 EcoTouch Insulation for MBI Plus products are not certified to the ASTM C991 standard or the NAIMA 202-96 Rev 2000 standard as these products are not designed to be post processed via lamination. Projects requiring certification to these standards should use unfaced Owens Corning EcoTouch Insulation for Certified R Metal Building 3 The surface burning characteristics of these products have been determined in accordance with ASTM E84, UL 723 or NFPA 255. These standards should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. Acoustic Data Sound Transmission Loss 1,2 Construction Type Clip Standoff (inches) Top Layer Insulation R-Value Bottom Layer Insulation R-Value Transmission Loss - dB at Octave Band Frequencies STC OITC 125 250 500 1000 2000 4000 Roofs Through Fastened NA 10 19 14 26 35 40 49 51 37 36 Through Fastened NA 19 30 18 32 42 50 57 42 41 Standing Seam 0.25 10 19 14 26 34 44 52 53 36 Standing Seam 1.25 19 30 19 32 42 56 63 58 42 41 Standing Seam 1.75 19 30 20 32 42 56 62 58 42 Construction Type Foam Tape Thickness (inches) Single Layer Insulation R-Value Transmission Loss - dB at Octave Band Frequencies STC OITC 125 250 500 1000 2000 4000 Walls Through Fastened 0.125 25 15 26 35 41 50 53 37 36 Through Fastened 0.375 30 17 29 38 45 54 39 38 1. Sound Transmission Loss Tested in accordance with ASTM E90. 2. Values are given for design approximations only. Production and test variabilities will alter the results.

Previous Page
Next Page