Division 7 Ebook Page 313 Trumbull® Asphalt Products

Always refer to the system manufacturer's recommended type of asphalt to be used for any given application. FOUR-PLY, GRAVEL-SURFACED FIBER GLASS BUILT-UP ROOF The following specification is for use over any type of approved non- nailable structural deck and approved non-nailable rigid roof insulation that offers a suitable surface to receive the roof. Poured and pre-cast concrete decks require priming prior to application of hot asphalt. This specification should not be used directly over poured or pre-cast gypsum or lightweight insulating concrete fills. Decks and/or substrate must be designed and installed to allow proper drainage to prevent water damage. Trumbull asphalt is always recommended and will be used as supplied, with the following information accompanying each palette of cartons (or bill of lading for bulk asphalt): ASTM type asphalt Typical flash point Manufacturing plant Typical EVT range at 125 cps and 75 cps Manufacturing date This material will comply with ASTM D312 specification for Built-Up Roofing asphalt. Selection of asphalt types should follow the guidelines found in ASTM 6510. Materials per 100 sq. ft. of roof area FELTS Fiber glass felts 4 plies ASPHALT (INTERPLY): TRUMBULL LOW-FUMING ASPHALT INCLINE PER FOOT ASPHALT MINIMUM WEIGHT 1 /4"-6" (7 to 152 mm) 200F, Type III, Steep 92 Ibs. (42 kg) or 220F, Type IV, Special Steep 1 /4"-6" (7 to 152 mm) PermaMop 92 Ibs. (42 kg) SURFACING Flood Coat of Asphalt 60 Ibs. (27 kg) Gravel 400 Ibs. (181 kg) Slag 300 Ibs. (136 kg) TYPICAL PHYSICAL CHARACTERISTICS FOR TRUMBULL ASPHALT Softening Point (F) Penetration Units: @ 32F @ 77F Flash Point (F) minimum typical Ductility @ 77F (cm) Solubility in Trichloroethylene % Typical Application Temperature for Hand Mopping EVT @ 125 CPS + _ 25F For Machine Spreader EVT @ 75 CPS + _ 25F* TYPE I Min. Max. 140 145 15 20 35 525 575 13.0 99.8 350 370 TYPE II Min. Max. 165 175 12 18 30 525 575 4.0 99.8 375 395 TYPE III Min. Max. 195 205 10 16 24 525 575 3.0 99.8 420 450 TYPE IV Min. Max. 210 225 8 13 22 525 575 2.0 99.8 445 475 PermaMop 215 235 12 18 525 575 7.0 97.5 375 395 PermaMop is FM and UL approved. Trumbull asphalt typically has EVTs in the following range for this product. For specific EVTs for a product from a particular Trumbull Plant, check our Web site at www.trumbullasphalt.com or call 1-800-GET-PINK. PHYSICAL REQUIREMENTS-ASTM D312 Softening Point (F) Flash Point (F) Penetration Units: @ 32F @ 77F @ 115F Ductility @ 77F (cm) Solubility in Trichloroethylene % TYPE I Min. Max. 135 151 500 - 3 - 18 60 90 180 10.0 - 99 - TYPE II Min. Max. 158 176 500 - 6 - 18 40 - 100 3.0 - 99 - TYPE III Min. Max. 185 205 500 - 6 - 15 35 - 90 2.5 - 99 - TYPE IV Min. Max. 215 225 500 - 6 - 12 25 - 75 1.5 - 99 - TEST Methods ASTM D36 ASTM D92 ASTM D5 ASTM D113 ASTM D2042 Asphalts shall be homogenous and free of water and shall conform to these physical properties. Pub. No. 10000113-A. Printed in U.S.A. February 2010. THE PINK PANTHER & 1964-2010 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2010 Owens Corning. OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-GET-PINK www.owenscorning.com/trumbull TYPICAL BUILT - UP ROOFING SPECIFICATION

Previous Page
Next Page