PAGE 20 1-800-GET-PINK www.owenscorning.com APPLICATION RECOMMENDATIONS INSULATION SYSTEMS FOR COMMERCIAL BUILDINGS Product Options FOAMULAR 250/400/600/1000 Insulation FOAMULAR LT30 or LT40 Insulation Installation & Design Considerations FOAMULAR 400, 600 and 1000 Insulation are for industrial applications where floor will experience heavy loads. Use FOAMULAR 250 Insulation in light commercial or residential applications where floors are subject to pedestrian or light working loads. To establish a stable, even base, use gravel fill. Gravel must be tamped thoroughly before installing insulation. Insulation board should be butted together tightly, and against adjacent vertical insulation surfaces or foundation walls. Building designer should determine the need for and placement of vapor retarders. VAPOR RETARDER UNDER FLOOR SLABS Product Options INSUL-DRAIN Insulating Drainage Board PINK-DRAIN Drainage Board FOAMULAR 250/400/600/1000 Insulation FOAMULAR DWB XPS Insulation Installation & Design Considerations For complete installation details, see the INSUL-DRAIN and PINK- DRAIN insulation drainage board product data sheets. Surrounding grades and/or concrete slabs should be sloped away from the foundation. Cover any insulation that is installed above grade. Typical coverings include siding, cementitious coatings or masonry veneers. VERTICAL FOUNDATION WALLS