Attachment to typical wall ties - Thermafiber RainBarrier Insulation can either be impaled onto shelf-type wall ties or installed so wall ties occur at insulation seams. Wall ties typically occur every 16" oc. Insulation is then secured to wall tie with Thermafiber RainBarrier Clip. * Please note that for systems requiring fire performance characteristics, galvanized steel retaining clips are recommended. Attachment to shelf-type wall ties - Thermafiber RainBarrier Insulation can either be impaled onto shelf-type wall ties or installed so wall ties occur at insulation seams. Wall ties typically occur every 16" oc. Insulation is then secured to wall tie with Thermafiber RainBarrier Clip * Please note that for systems requiring fire performance characteristics, galvanized steel retaining clips are recommended. RainBarrier Brick Veneer Anchor Thermafiber Attachment to Brick-Veneer anchor wall - Thermafiber RainBarrier Insulation to be attached to CMU wall with brick tie wall anchors. Insulation is secured to CMU wall by screwing the anchor screw with minimum 1 " diameter head to the CMU anchor. Screws are typically spaced every 16" oc. + CMU/Brick Veneer Wall Tie Application + Steel Stud/Brick Veneer Wall Tie Application Air/Vapor Barrier RainBarrier Thermafiber RainBarrier Clip Thermafiber RainBarrier Thermafiber RainBarrier Clip Thermafiber Brick Tie/Masonry Anchor Installation