Division 7 Ebook Page 113 EcoTouch® Flame Spread 25 Product Data Sheet

PRODUCT DATA SHEET EcoTouch Flame Spread 25 Fiberglas Insulation Description Owens Corning EcoTouch Flame Spread 25 Fiberglas Insulation is a preformed, flexible blanket insulation. It is produced in R-values from 11 to 49, at thickness from 3 to 11 inches. It is available with either a FSK (foil-scrim-kraft) or PSK (poly-scrim-kraft) facing; both of which act as vapor retarders and provide a neat, finished appearance. Features Excellent thermal control Effective acoustical performance Provides long term performance and will not settle nor slump within wall cavities Less dust than other fiberglass insulation products Excellent recovery characteristics 1 Compression packaging speeds job site handling and installation 1. According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf of Owens Corning Insulation Systems, LLC. Applications Wall, floor and roof/ceiling assemblies where the insulation will be left exposed, or where a low flame spread vapor retarder facing is required Concealed applications of assemblies for non- combustible construction Wood and metal framed assembly cavities, or attached to surfaces with impaling pins Standards, Codes Compliance Manufactured in compliance with ASTM C 665 Federal Specification HH-I-521F has been canceled and replaced by ASTM C 665 Classified noncombustible when tested in accordance with ASTM E 136 EcoTouch Flame Spread 25 insulation is accepted for use in all ICC building construction types (1 through V) Certified to meet California Code of Regulations, Title 24, Chapter 12-13, Article 3, "Standards for Insulating Material" Design Considerations The building thermal barrier (insulation) should be in continual alignment with the building air barrier In framed cavities product thickness should match the depth of the framing members Follow the local, applicable building code(s) to determine the need for and placement of a vapor retarder Do not install insulation on top, or within 3 inches of a recessed light fixture unless the fixture is labeled as "insulation contact" (IC) rated Physical Properties Property (unit) Test Value Thermal Resistance ASTM C518 See "Availability" table for R-values Surface Burning Characteristics (flame spread/smoke developed) ASTM E84 1 FSK <25/<50 PSK <25/<50 Critical Radiant Flux (W/cm 2 ) ASTM E970 >0.12 Water Vapor Permeance (perms) FSK ASTM E96 2 .5 PSK ASTM E96 2 .5 Water Vapor Sorption (by weight) ASTM C1104/ C1104M <5% Odor Emission ASTM C1304 pass Corrosion Resistance ASTM C665, part 13.8 pass Fungi Resistance (fiberglass only) ASTM C1338 pass 1. ASTM E84 is used solely to measure and describe properties of products in response to heat and flame under controlled laboratory conditions, and should not be used to describe or approve the fire hazard of materials under actual fire conditions. However, the results of these tests may be used as elements of a fire risk assessment that takes into account all of the factors of the fire hazard of a particular end use. Values are reported to the nearest five rating. 2. Dessicant method Classifications ICC Bldg. Construction ASTM C665 FSK All Types Type III, Class A, Cat. 1 PSK Type III, VI, V Type II, Class A, Cat. 1

Previous Page
Next Page