Division 7 Ebook Page 11 Insulation Systems for Commercial Buildings

PAGE 6 1-800-GET-PINK www.owenscorning.com SOUND ATTENUATION BATT INSULATION FIBERGLASS INSULATION-PRODUCT DATA DESCRIPTION & USES SAB Unfaced Designed to deliver noise control in standard metal-framed interior partitions, SABs are slightly wider than stud spaces and up to 9' long to accommodate easy, friction-fit installation. Lightweight, flexible fiberglass insulation batts, Owens Corning Sound Attenuation Batts/SABs are manufactured in thicknesses of 2", 3" and 5". FEATURES & BENEFITS Sound Attenuation Batts can improve Sound Transmission Class (STC) ratings by 4 to 10 points, depending on the construction method used. See next page for STC performance data. Classified as noncombustible by model building codes. When installed in wall systems and tested per ASTM E119, assembly fire resistance ratings up to 2 hours can be achieved. Sound Attenuation Batt Surface Burning Characteristics meet the code requirements for all building types as described by the Standard Building Code (SBCCI), the National Building Code (BOCA), the Uniform Building Code (ICBO) and the International Building Code (IBC). Adhesives and fasteners are not required. Easily cut or split to fit around wires, pipes, electrical service boxes and other obstructions, SABs are simply placed in the metal stud framing cavity for a friction-fit. Adds thermal value in applications where a temperature differential exists. SOUND ATTENUATION BATT INSULATION TECHNICAL DATA WIDTH(S) LENGTH THICKNESS 16" 406 mm 24" 609 mm 96" 2438 mm 3" 89 mm 16" 406 mm 24" 609 mm 96" 2438 mm 2" 64 mm 16" 406 mm 24" 609 mm 108" 2438 mm 2" 64 mm 16" 406 mm 24" 609 mm 108" 2438 mm 3" 64 mm 1. R-values differ. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power. R-value ASTM C518 Sound Attenuation Batt Insulation complies with the property requirements of ASTM C665, Type I and ASTM E136. SURFACE BURNING CHARACTERISTICS/BUILDING CODE CONSTRUCTION CLASSIFICATIONS PRODUCT TYPES FLAME SPREAD SMOKE DEVELOPED ICBO BOCA SBCCI ICC Unfaced 10 All Types Sound Attenuation Batt Insulation complies with the International Building Code (ICC), Uniform Building Code (ICBO), National Building Code (BOCA) and Standard Building Code (SBCCI) model code requirements for building construction types listed above. WATER VAPOR SORPTION Maximum by Weight 5% DIMENSIONAL STABILITY Linear Shrinkage Less than 0.1% Products are tested in accordance with: Surface Burning Characteristics ASTM E84. STEEL STUD STC TEST NO. CONSTRUCTION DESCRIPTION FIRE TEST FIRE RATING DOUBLE LAYER WALL SYSTEM 56 TL-93-351 5 /8" Type "X" gypsum; 3 5 /8" SS, 3" thick Sound Attenuation Batt Insulation UL-U423 2 Hr. 54 NBC No. S3a 5 /8" Type "X" gypsum; 2" SS, 2" thick Sound Attenuation Batt Insulation NBC No. S3a 2 Hr. UNBALANCED WALL SYSTEM (2 LAYER/1 LAYER OF GYPSUM) 54 TL-92-368 Unbalanced 5 /8" Type "X" gypsum; 3 5 /8" SS, 3" thick, Sound Attenuation Batt Insulation UL-U465 1 Hr. 51 TL-93-036 Unbalanced 5 /8" Type "X" gypsum; 2" SS, 2" thick, Sound Attenuation Batt Insulation ULC W409 1 Hr. SINGLE LAYER WALL SYSTEM 49 TL-92-349 Single layer 5 /8" Type "X" gypsum; 3 5 /8" SS, 2" thick, Sound Attenuation Batt Insulation UL U465 1 Hr. 44 TL-93-033 Single layer 5 /8" Type "X" gypsum; 2" SS, 2" thick, Sound Attenuation Batt Insulation ULC W409 1 Hr.

Previous Page
Next Page