Division 22 23 Ebook Page 99 HVAC Product Catalog

QUIETR DUCT LINER BOARD QuietR Duct Liner Board is a bonded board of glass fibers designed to be installed inside sheet metal ductwork or plenums with metal fasteners and adhesives. It is used in large duct and plenums and has an air velocity rating of 6,000 FPM (30.5 m/s). Key Features Outstanding thermal and acoustical performance Absorbs noise within the duct that helps create quiet and comfortable environments Cleanable surface with a black mat facing that provides a smooth, durable surface making it easier to clean the duct liners using methods and equipment described in North American Insulation Manufacturers Association (NAIMA) Publication AH122, Cleaning Fibrous Glass Insulated Duct Systems: Recommended Practice Bacterial and fungal growth resistant with an EPA registered biocide that protects the airstream surface from microbial growth New, dark veil that is strong with a durable air stream Standards, Codes Compliance ASTM C1071, Type II Rigid ICC Compliant California Title 24 SMACNA Application Standard for Duct Liners NAIMA Fibrous Glass Duct Liner Installation Standard Conforms to ASHRAE 62-2001 Owens Corning duct liners have flame spread ratings of 25 and smoke developed ratings of 50 when tested in accordance with UL 723 and ASTM E84. They meet requirements of NFPA 90A and 90B for fire resistance Meets requirements of ASTM C1338, ASTM G21 (fungi test), and ASTM G22 (bacteria test) THERMAL PERFORMANCE QuietR Duct Liners are available in the following combinations of thicknesses and types: R-values, hrft 2 F/Btu (RSI, m 2 C/W) at 75F (24C) mean temperature Product Type and Thickness Normal Density pcf(kg/m 3 ) 1 in (25 mm) 1.5 in (38mm) 2 in (51mm) QuietR Duct Liner Board 3 (48) 4.3 (0.76) 6.5 (1.15) 8.7 (1.53) QuietR Duct Liner Board is available in the following standard sizes: 1.5" x 48" x 96" (38mm x 1219mm x 2438mm), 2" x 24" x 48" (51mm x 610mm x 1219mm), and 2" x 48" x 96" (51mm x 1219mm x 2438mm) MTO available at Width: 48", Length: 24" - 120" QUIETR DUCT BOARD Owens Corning QuietR Duct Board is a rigid, resin bonded fibrous glass board with a tough, damage-resistant, flame retardant, reinforced aluminum foil (FRK) facing. When fabricated into duct systems, it combines excellent thermal and acoustical insulating properties with substantially airtight transmission of air when all joints are sealed with UL 181A listed closures. Key Features Virtually eliminates air leakage thus saving heating and cooling costs * Only manufacturer that has a 1" Type 800 duct board produced for light commercial applications Assured thermal R-value performance Absorbs noise and reduces popping noises caused by expansion, contraction and vibration Thermal/acoustical insulation board plus jacket forms a single component duct system, thus reducing inspection time Lightweight boards are easier to transport and handle than insulated sheet metal ducts* Bacterial and fungal growth resistant with an EPA registered biocide that protects the air stream surface from microbial growth Standards, Code Compliance Meets NFPA 90A/90B Meets ICC International Mechanical Code, Corps of Engineers Guide Spec., NYC MEA #186-69 Supported by NAIMA and SMACNA industry standards Meets requirements of ASTM C1338, ASTM G21 (fungi test) and ASTM G22 (bacteria test) *Savings vary. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power. Visit http://www.energystar.gov/index.cfm?c=home_sealing.hm_improvement_methodology. THERMAL PERFORMANCE Property 1" (25mm) 1.5" (38mm) 2" (51mm) R-value, hrft 2 F/Btu (RSI, m 2 C/W) 4.3 (0.76) 6.5 (1.15) 8.7 (1.53) k-value, Btuin/hrft 2 F (W/mC) 0.23 (0.033) C-value, Btu/hrft 2 F (W/m 2 C) 0.23 (1.32) 0.16 (0.87) 0.12 (0.65) Mean temperature is the average of two temperatures: that of the air inside the duct and that of the ambient air outside it. Note: Specified design thickness should be adequate to prevent exterior surface condensation. PHYSICAL PROPERTY DATA Property Test Method Value Maximum Operating Temperature Limits UL 181/ULC S110 Internal: 250F (121C) External: 150F (66C) Maximum Air Velocity UL 181/ULC S110 Erosion Test 6,000 fpm (30.5 m/s) Static Pressure Limit UL 181/ULC S110 2 in. w.g. (500 Pa) Water Vapor Sorption (by weight) ASTM C1104 <3% at 120F (49C), 95% R.H. Mold Growth UL 181/ULC S110 Meets requirements Fungi Resistance ASTM G21 Meets requirements Bacteria Resistance ASTM G22 Meets requirements Surface Burning Characteristics 1 Flame Spread Smoke Developed UL 723/ULC S102 < 25 1 < 50 Fire Retardancy UL 181/ULC S110 Flame Penetration 30 min. 1. The surface burning characteristics of these products have been determined in accordance with UL 723/ULC S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. PHYSICAL PROPERTY DATA Property Test Method Value Operating Temperature ASTM C411 250F (121C) Maximum Air Velocity UL 181 and ASTM C1071 Erosion Test 6,000 fpm (30.5 m/s) Water Vapor Sorption (by weight) ASTM C1104 3% at 120F (49C), 95% R.H. Fungi Resistance ASTM C1338 Meets requirements Fungi Resistance ASTM G21 Meets requirements Bacteria Resistance ASTM G22 Meets requirements Corrosiveness 1 ASTM C665 Corrosiveness Test Will not cause corrosion greater than caused by sterile cotton on aluminum or steel Thermal Conductivity k at 75F ( at 24C mean) ASTM C518 Btuin/hrft 2 F W/mC 0.23 0.033 Surface Burning Characteristics 2 Flame Spread Smoke Developed ASTM E84, NFPA 255, UL 723, and CAN/ULC-S102 25 50 1. When wet, coated surfaces of QuietR Duct Liner Board in contact with galvanized steel may cause discoloration of the sheet metal. 2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E 84, NFPA 255, and CAN/ ULC-S102. These standards should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.

Previous Page
Next Page