Division 22 23 Ebook Page 52 Pipe and Mechanical Insulation Brochure

25 Physical property data Property Value Test Method Equipment Operating Temperature Limitation 1 0 to 450 F (-18 C to 232 C) ASTM C411 Insulation Jacket Temperature Limitation -20 F to 150 F (-29 C to 66 C) ASTM C1136 Jacket Permeance 0.02 perm ASTM E96, Proc. A Jacket Burst Strength FRK: 35 psi; ASJ Max: 100 psi ASTM D774 Compressive Strength (minimum) at 10% deformation at 25% deformation Type 703 25 lb/ft 2 (1197 Pa) 90 lb/ft 2 (4309 Pa) Type 705 200 lb/ft 2 (9576 Pa) - ASTM C165 Water Vapor Sorption <2% by weight at 120F (49C), 95% R.H. ASTM C1104 Nominal Density Type 701: 1.5 pcf (24 kg/m 3 ) ASTM C167 Type 703: 3.0 pcf (48 kg/m 3 ) ASTM C303 Type 705, 706: 6.0 pcf (96 kg/m 3 ) Type 707: 7.0 pcf (112 kg/m 3 ) Surface Burning Characteristics 2 Flame Spread: 25 Smoke Developed: 50 UL 723, ASTM E84 or CAN/ULC-S102 1. Maximum thickness at 450 F (232 C): Type 701: 6" (152mm); Type 703, 705, 706: 4" (102mm). 2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. SPECIFICATIONS Thermal performance ASTM C680 (Type 703) Operating Temperature, F ( C) Thickness 250 (121) 300 (149) 350 (177) 400 (204) 450 (232) in. (mm) HL ST HL ST HL ST HL ST HL ST 1.0 (25) 27 98 42 106 57 114 75 123 95 133 1.5 (38) 19 93 29 99 40 105 52 112 66 119 2.0 (5l) 15 90 22 95 31 100 40 105 50 111 2.5 (64) 12 88 18 92 25 96 32 101 41 106 3.0 (76) 10 87 15 91 21 94 27 98 34 102 3.5 (89) 9 86 13 89 18 92 23 96 30 99 4.0 (102) 8 86 11 88 16 91 21 94 26 97 The above table provides approximate heat loss values (HL), Btu/hr ft 2 , and Surface Temperatures (ST), F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80F ambient temperature, still air, ASJ Max facing. To convert heat loss values to W/m 2 , multiply values by 3.15. To convert surface temperatures, use the formula: C = (F-32)/1.8. For similar information using other assumptions, contact your Owens Corning Representative. 700 Series Fiberglas Insulation

Previous Page
Next Page