Division 22 23 Ebook Page 208 Section 22 07 19 Plumbing Piping Insulation-Fiberglasí Insulation

PLUMBING PIPING INSULATION 22 07 19 - 1 Plumbing Piping Insulation - FIBERGLAS Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the engineer. Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated com- panies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construc- tion related details, whether based upon the information provided by Owens Corning or otherwise. SECTION 22 07 19 PLUMBING PIPING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Provide the following: Note to Specifier: The following temperature ranges are typical for these systems. However, if project requirements call for service temperatures outside the ranges listed, consult the manufacturer's published data to determine operating temperature limitations of the insulation product or products under consideration. 1. Cold Piping Systems (chilled water, brine, refrigerant), 32F (0C) to 65F (18C). 2. Dual Temperature Systems, 32F (0C) to 220F (104C). 3. Heating Systems (steam, steam condensate, hot water), ambient up to 450F (232C). 4. Domestic and Service Hot Water Systems, ambient up to 180F (82C). B. Items Not Insulated: Unless otherwise indicated, do not install insulation on the following: 1. Drainage piping located in crawl spaces. 2. Underground piping. 3. Chrome-plated pipes and fittings unless there is a potential for personnel injury. 1.2 REFERENCES A. Materials shall meet the property requirements of one or more of the following specifications as applicable to the specific product or end use: 1. American Society for Testing of Materials (ASTM): a. ASTM C547, Standard Specification for Mineral Fiber Pipe Insulation. b. ASTM C585, Standard Practice for Inner and Outer Diameters of Rigid Thermal Insulation for Nominal Sizes of Pipe and Tubing (NPS System). c. ASTM C795, Standard Specification for Thermal Insulation for Use in Contact with Austenitic Stainless Steel. d. ASTM C1338, Standard Test method for Determining the Fungi Resistance of Insulation Materials and Facings. e. ASTM C1393, Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks. f. ASTM E84, Standard Test Method for Surface Burning Characteristics of Building Materials.

Previous Page
Next Page