Division 22 23 Ebook Page 201 NAHB/ANSI Approved 2008 National Green Building Standard Reference Guide

Green Building Category Resource Efficiency Energy Efficiency Indoor Environmental Quality National Green Building Standard ICC 700-2008 Key: Product is Certified by Home Innovation Laboratory for the Practice Product, in use with other products and good design and construction practices, can contribute to meeting Practice Requirements Enhanced Durability, Water Resistive Barrier/ Drainage Plane Enhanced Durability, Ice Barrier Enhanced Durability, Flashing details Enhanced Durability, Energy Star Cool Roof Enhanced Durability, Vegetated Roof Recycled Content Building Materials Renewable Materials, Biobased Products Life Cycle Analysis Insulation and Air Sealing, Insulation installation Insulation & Air Sealing, Shafts (duct shaft, piping shaft/penetrations, flue shaft) Insulation and Air Sealing, Insulate Floors, Foundations & Crawlspaces Insulation and Air Sealing, Windows and doors Insulation & Air Sealing, Band Joist and Rim Joist Insulate and Air Sealing, Foundation and Sill Bottom Plate Insulation and Air Sealing, Skylight Shafts and Knee Walls Insulation and Air Sealing, Attic Access insulation Insulation and Air Sealing, Baffles for Eave Vents Performance Path: Energy Cost Performance exceeds ICC IECC levels, documented Prescriptive Path: Building Thermal Envelope Exceeds ICC IECC, Graded and Documented Analysis Insulation & Air Sealing Installation Boiler Supply Piping Insulated in Unconditioned Spaces Building Envelope Leakage Rate, Measured ACH50 HVAC Duct Leakage Tested Performance Pollutant Source Control, Attached Garage Continuous Air Barrier Pollutant Source Control, Interior Low VOC Sealants Pollutant Source Control,Building & Duct Insulation Formaldehyde Emissions Pollutant Control, Contaminants Sealed From Living Space HVAC Duct Insulation, Min. R-6 Duct Insulation, Points for R-8 Practice Number, Version 2008 602.9 602.10 602.12 602.13 (1) 602.13 (2) 604.1 606.1 609.1 701.4.3.1(1) 701.4.3.1(2) 701.4.3.2 701.4.3.3(1) 701.4.3.3(2) 701.4.3.3(3) 701.4.3.3(4) 701.4.3.4(1) 701.4.3.4(3) 702.2 703.1 703.2 703.5.4.2 704.6.2.1(4) 704.6.2.2 901.3(1)b 901.9.2 901.11 902.6 903.6 NEW CONSTRUCTION (Mandatory or Points) Mandatory Mandatory 6 Points 3 Points 3 Points 1 to 18 points 0 - 8 Points Max 15 Points Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory 30 - 120 points 0 - 36 Points 3 - 15 Points 1 Point 3 - 15 Points 5 - 15 Points Mandatory, 2 5 Points 5 Points 2 - 6 Points Mandatory, 2 Insulating Products Fiberglass Insulation: EcoTouch PINK FIBERGLAS Thermal Batts & Rolls insulation Mineral Wool Insulation: Thermafiber UltraBatt Insulation Fiberglass Insulation: PROPINK L77 Loosefill Insulation, AttiCat Expanding Blown-In Loosefill Insulation Air Sealing System: EnergyComplete Sealant Foam Insulation: FOAMULAR Extruded Polystyrene (XPS) Insulation raft-R-mate Eave Baffles FlashSealR Flashing Tape FoamSealR Sill Plate Gasket HVAC Insulation: QuietR Duct Liner Board, QuietR Textile Duct Liner, QuietR Rotary Duct Liner, QuietR Duct Board, QuietZone Spiral Duct Liner, SoftR Duct Wrap & EcoTouch Insulation for Flexible Duct Pipe Insulation: Fiberglas SSL 1 & SSL11 Pipe Insulation with All Service Jacket (ASJ) Roofing Products Shasta White Only in Classic Shingles, Supreme Shingles, Duration Shingles & Oakridge Shingles; Duration Premium Cool Shingles only in Sunrise, Frosted Oak & Harbor Fog Colors WeatherLock Ice & Water Barrier Products Green Building Category Resource Efficiency Energy Efficiency Indoor Environmental Quality Remodeling National Green Building Standard ICC 700-2012 Key: Product is Certified by Home Innovation Laboratory for the Practice Product, in use with other products and good design and construction practices, can contribute to meeting Practice Requirements Enhanced Durability, Water Resistive Barrier/ Drainage Plane Enhanced Durability, Ice Barrier Enhanced Durability, Flashing details, Window Head and Jamb Enhanced Durability, Flashing details, Rain Screen Enhanced Durability, Energy Star Cool Roof Enhanced Durability, Vegetated Roof Recycled Content Building Materials Renewable Materials, Biobased Products Regional Materials Life Cycle Analysis Innovative Practices, Sustainable Products, EcoLogo CCD-016 Minimum Energy Efficiency Requirements, Building Thermal Envelope Sealing Minimum Energy Efficiency Requirements, Air Sealing and Insulation, Testing Option for Air Tightness Minimum Energy Efficiency Requirements, Air Sealing and Insulation, Visual Inspection Option for Air Tightness Minimum Energy Efficiency Requirements, Air Sealing and Insulation, Recessed Lighting Performance Path: Energy Cost Performance exceeds ICC IECC levels, documented Prescriptive Path: Building Thermal Envelope Exceeds ICC IECC, Graded and Documented Analysis Insulation & Air Sealing Installation Boiler Supply Piping Insulated in Unconditioned Spaces Prescriptive Path, Building Envelope Leakage Rate, Measured ACH50 Additional Practices, Insulating Hot Water Pipes HVAC Duct Leakage Tested Performance Pollutant Source Control, Attached Garage Continuous Air Barrier Pollutant Source Control, Interior Low VOC Sealants Pollutant Source Control,Building & Duct Insulation Formaldehyde Emissions Pollutant Control, Contaminants Sealed From Living Space HVAC Duct Insulation, Min. R-6 Duct Insulation, Points for R-8 Recycled Construction Waste Practice Number, Version 2008 602.1.8 601.1.13 602.1.9 (2) 602.1.9 (5) 602.2 (1) 602.2 (2) 604.1 606.1 609.1 610.1.2 611.2 (3) 701.4.3.1 701.4.3.2(1) 701.4.3.2 (2) 701.4.3.4 702.2 703.1.1 703.1.2 701.4.5 703.1.5 704.5.3 703.3.4 901.3(1)b 901.10 901.11 902.6 903.2 (3) 11.605 NEW CONSTRUCTION (Mandatory or Points) Mandatory Mandatory 2 Max 4 Points 3 Points 3 Points 1 to 18 points 0 - 8 Points Max 10 Points Max 15 Points 3 Points Mandatory Mandatory Mandatory Mandatory 30 - 100 Points 0 - 18 Points 3 - 15 Points Mandatory 2 - 24 Points 1 Point 1 - 8 points Mandatory, 2 8 Points 5 Points Mandatory 3 Points Max 6 Points Insulating Products Fiberglass Insulation: EcoTouch PINK FIBERGLAS Thermal Batts & Rolls insulation Mineral Wool Insulation: Thermafiber UltraBatt Insulation Fiberglass Insulation: PROPINK L77 Loosefill Insulation, AttiCat Expanding Blown-In Loosefill Insulation Air Sealing System: EnergyComplete Sealant Foam Insulation: FOAMULAR Extruded Polystyrene (XPS) Insulation FlashSealR Flashing Tape FoamSealR Sill Plate Gasket HVAC Insulation: QuietR Duct Liner Board, QuietR Textile Duct Liner, QuietR Rotary Duct Liner, QuietR Duct Board, QuietZone Spiral Duct Liner, SoftR Duct Wrap & EcoTouch Insulation for Flexible Duct Pipe Insulation: Fiberglas SSL 1 & SSL11 Pipe Insulation with All Service Jacket (ASJ) Roofing Products Shasta White Only in Classic Shingles, Supreme Shingles, Duration Shingles & Oakridge Shingles; Duration Premium Cool Shingles only in Sunrise, Frosted Oak & Harbor Fog Colors WeatherLock Ice & Water Barrier Products Owens Corning Shingle Recycling Program

Previous Page
Next Page