Division 22 23 Ebook Page 199 California 2010 Green Building Standards Code Product Guide

California 2010 Green Building Standards Code. Owens Corning Can Help Meet CALGreen. CATEGORY AND DESCRIPTION MANDATORY / ELECTIVE TIER 1 TIER 2 OWENS CORNING PRODUCT APPLICATIONS 4.1 PLANNING AND DESIGN In addition to General mandatory measures, builder must comply with Tier 1 mandatory measures and choose 2 elective measures from section 4.1 In addition to General mandatory measures, builder must comply with Tier 2 mandatory measures and choose 4 elective measures from section 4.1 A4.106.5 Roofing materials 3 year aged solar reflectance and thermal emittance equal to/exceeds table 4.106.5(1) or (2) Elective Tier 1 roof covering shall meet or exceed the values in Table A4-106.5(1) Tier 2 roof covering shall meet or exceed the values in Table A4-106.5(2) Cool Roof Shingles in Harbor Fog, Frosted Oak, Sunrise and Sage; Shasta White in Classic , Supreme , Oakridge , Duration and Duration Premium 4.2 ENERGY EFFICIENCY In addition to General mandatory measures, builder must comply with Tier 1 mandatory measures and comply with 4 elective measures from section 4.2 In addition to General mandatory measures, builder must comply with Tier 2 mandatory measures and choose 6 elective measures from section 4.2 4.201.1 Low-rise residential shall meet Title 24, Part 6; exceed it for Tiers 1 or 2 MANDATORY Builder must exceed Title 24, Part 6 by 15%, increased envelope sealing and insulation systems, insulated ductwork, energy efficient windows and cool roofs are among the best and cost effective methods help builder get to 15% Builder must exceed Title 24, Part 6 by 30%, increased envelope sealing and insulation systems, insulated ductwork, energy efficient windows and cool roofs are among the best and cost effective methods help builder achieve this level of energy efficiency EcoTouch attic, walls and floor insulation, L77, PRO PINK Complete or AttiCat blown in fiberglass insulation; FOAMULAR rigid exterior wall and foundation insulation; EnergyComplete ; PINK WRAP housewrap; Cool Roof Shingles in Harbor Fog, Frosted Oak, Sunrise and Sage; Shasta White in Classic , Supreme , Oakridge , Duration and Duration Premium; Flexible Duct with EcoTouch Insulation and QuietR Duct Board, QuietR Duct Liner Board, SoftR Duct Wrap FRK A4.206.1 Air Sealing Package: Third party blower door test conducted and passed to verify tightness to Title 24 Standard Elective EnergyComplete System with Flexible Seal Technology provides decreased infiltration-used in conjunction with EcoTouch batts and rolls, or PRO PINK Loosefill; FOAMULAR XPS insulation provides thermal protection and air infiltration control A4.207.7 HVAC Design, Equipment & Installation: Higher insulated duct work Elective Builder must exceed Title 24 by 15%, increased duct insulation to an R-6 or R-8 is one of the best and cost effective methods help builder get to this level of energy efficiency Builder must exceed Title 24 by 30%, increased duct insulation to an R-6 or R-8 is one of the best and cost effective methods help builder get to 30% Flexible Duct with EcoTouch Insulation, QuietR Duct Board, QuietR Duct Liner Board and SoftR Duct Wrap FRK. California Homebuilders can gain significant credits by moving from R-4.2 to R-6 insulated ducts in attics. R-6 is one of the top 10 energy efficiency measures to pick within Title 24, across all 16 zones and compare well in energy bang for buck A4.207.8 Perform duct leakage test 6% or less of total fan flow Elective QuietR Duct Board with UL181A closure system provides a sealed air distribution duct system complying with duct leakage requirements and improved condition air delivery performance 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY In addition to General mandatory measures, builder must comply with Tier 1 mandatory measures and choose 2 elective measures from section 4.4 In addition to General mandatory measures, builder must comply with Tier 2 mandatory measures and choose 4 elective measures from section 4.4 A4.403.1 Frost protected shallow foundation (FPSF) is designed and constructed Elective FOAMULAR XPS foam is specified for frost protection A4.405.3 Use materials with post-consumer or pre-consumer recycled content value (RCV) for a minimum of 10 or 15 percent of the total value, based on estimated cost of materials on the project. Elective Not less than 10% post or pre-consumer recycled content value (RCV) Not less than 15% post or pre-consumer recycled content value (RCV) EcoTouch insulation minimum 58% (faced) or 65% (unfaced) SCS certified recycled content, 36% (faced) or 41% (unfaced) post-consumer, Heavy density fiberglass insulation and air handling products have 57% SCS certified Pre-consumer recycled content; FOAMULAR minimum 20% SCS certified Pre-consumer recycled content 4.406.1 Enhanced Durability and Reduced Maintenance: Seal joints and openings (spaces around pipes, electric cables, conduits or other) to protect against passage of rodents MANDATORY EnergyComplete System with Flexible Seal Technology provides sealing capability for gaps up to 3 /8" for decreased infiltration and protection from insects and rodents; FOAMULAR XPS insulation provides thermal protection and air infiltration control A4.407.5 Water Resistance and Moisture Management: Climate Zone 16, provide ice/water barrier at roof valleys and wall to roof intersections Elective WeatherLock Flex Flexible Self-Sealing Ice & Water Barrier; WeatherLock Specialty Tile & Metal underlayment and the full line of WeatherLock products, other Roofing Essentials accessory products 4.408.1 Waste Management: Minimum 50% construction waste generated diverted or recycled; A4.408.1 Higher percentages of construction waste diverted or recycled MANDATORY 50% construction waste diverted 65% construction waste diverted 75% construction waste diverted Shingle Recycling program with Heritage Environmental-California locations coming soon 4.408.2 Waste Management: Construction waste diversion plan required where local jurisdiction has none MANDATORY Shingle Recycling program with Heritage Environmental-California locations coming soon 4.5 ENVIRONMENTAL QUALITY In addition to General mandatory measures, builder must comply with Tier 1 mandatory measures and choose 1 elective measures from section 4.5 In addition to General mandatory measures, builder must comply with Tier 2 mandatory measures and choose 1 elective measures from section 4.5 4.504.2.1 Adhesives, sealants and caulks low VOC MANDATORY EnergyComplete System with Flexible Seal Technology is GREENGUARD certified for indoor air quality and carries the GREENGUARD SM Children and Schools certification 4.504.2.4 Documentation provided to prove low VOC MANDATORY A wide range of Owens Corning products carry the GREENGUARD and GREENGUARD SM Children and Schools certification; EcoTouch fiberglass insulation and L77, Flexible Duct* with EcoTouch Insulation, PRO PINK Complete and AttiCat loosefill insulation are all verified to be formaldehyde-free by GREENGUARD Environmental Institute A4.504.3 Thermal insulation installed meets low VOC for CHPS contains no added formaldehyde Elective Thermal Insulation installed meets low VOC defined in Collaborative for High Performance Schools (CHPS) Low- emitting Materials List Thermal Insulation installed contains no added formaldehyde and compliant with VOC- emission limits defined in Collaborative for High Performance Schools (CHPS) Low- emitting Materials List A wide range of Owens Corning products carry the GREENGUARD and GREENGUARD SM Children and Schools certification; FOAMULAR XPS foam insulation is made without formaldehyde; EcoTouch fiberglass insulation and L77, Flexible Duct* with EcoTouch Insulation, PRO PINK Complete and AttiCat loosefill insulation are all verified to be formaldehyde-free by GREENGUARD Environmental Institute 4.505.2.1 Vapor retarder and capillary break on slab on grade foundations MANDATORY FOAMULAR XPS foam is used under slab as a capillary break, vapor retarder and offers thermal protection *Insulation Only

Previous Page
Next Page