Division 22 23 Ebook Page 123 Fiberglasí Pipe Insulation Product Data Sheet

Product Data Sheet FIBERGLAS Pipe Insulation ASJ Max ASJ Max for Aquatherm No Wrap No Wrap Vacuum Pack Description Owens Corning FIBERGLAS Pipe Insulation is molded of heavy density resin bonded inorganic glass fibers. The one-piece, 36" (914mm) long, hinged sections are opened, placed over the pipe, closed and secured by means specific to the type as described below. ASJ Max FIBERGLAS Pipe Insulation has an encapsulated- paper, vapor-retarder jacket that is smooth, durable, cleanable, wrinkle-resistant, resists water staining and doesn't support mold or mildew growth. 2 It is also available in select metric sizes for use with Aquatherm pipe systems. (See dimensional data sheet for metric sizing availability. Pub. No. 10018078.) The ASJ Max jacket features the SSL Max closure system which provides a positive-mechanical closure and vapor seal of the longitudinal jacket seam. It was designed with advanced adhesives to work specifically with the new jacket to provide a tight, reliable seal that doesn't need glue or staples. Pressure sensitive butt strip seals complete the positive closure system. No Wrap FIBERGLAS Pipe Insulation doesn't have a jacket and is intended for field installation with jacketing appropriate to the vapor control, damage, or corrosion resistance requirements of the application. No Wrap Vacuum Pack is compression packaged inside a poly bag utilizing a vacuum. This results in a product that can be shipped and stored more efficiently.* Key Features The ASJ Max jacket is tougher 1 than standard ASJ. It has a polymer coating that helps resist water staining and does not support mold or mildew growth 2 . ASJ Max is designed to have a compatible finished job appearance with standard ASJ. SSL Max closure system is fast, neat and combines with the butt strips to provide effective long term vapor sealing of the longitudinal and butt joints. Short pieces of insulation can be cut without jacket loss and the section will not come apart in handling. Butt strips come in sealed bags inside the carton so they can stay clean until the moment of use. FIBERGLAS Pipe Insulation's low thermal conductivity contributes to lower operating costs of heating and cooling equipment. ASJ Max can resist short durations of liquid water exposure that can occur during construction. This product does not contain decaBDE. UL Labeled for flame spread rating of 25 or less and smoke developed rating of 50 and is full building code compliant. Product Applications Insulation of hot, cold, concealed and exposed piping operating at temperatures from 0F (-18C) to 1,000F (538C) (with heat-up schedule) in commercial buildings, industrial facilities, and process or power plants. Installation Instructions ASJ Max 1. Ambient application temperatures are from 25F (-4C) to 110F (43C). 2. Open the hinged sections and place the insulation over the pipe, taking care not to get dirt, dust or moisture on the overlap area. 3. Pull the release strip from the lap. While preparing to close the insulation, take care not to allow the adhesive to contact anything until the insulation is properly lined up and closed over the pipe. * The No Wrap Vacuum Pack packaging process may cause some breakdown of the mechanical properties, such as the hinge, or cause additional dust in the package. It also may impact the outside diameter of the insulation pertaining to ASTM C585. The user assumes all responsibility for meeting project insulation requirements. 1. Based on burst strength testing. 2. ASJ Max jacket does not support mold growth when tested in accordance with ASTM C1338.

Previous Page
Next Page