Division 22 23 Ebook Page 114 Fiberglasí SCR Insulation Board Product Data Sheet

Fiberglas SCR Insulation Board Product Data Sheet Certifications and Sustainable Features of Fiberglas SCR Insulation Board Certified by SCS Global Services to contain a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer. Environmental and Sustainability Owens Corning is a worldwide leader in building material systems, insulation and composite solutions, delivering a broad range of high- quality products and services. Owens Corning is committed to driving sustainability by delivering solutions, transforming markets and enhancing lives. More information can be found at http:// sustainability.owenscorning.com. OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-GET-PINK www.owenscorning.com Pub. No. 57285-E. Printed in U.S.A. December 2014. THE PINK PANTHER & 1964-2014 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2014 Owens Corning. All Rights Reserved. Thermal Conductivity Mean Temp, F k, Btuin/(hrft 2 F) Mean Temp, C , W/mC 75 .23 25 0.033 100 .24 50 0.037 200 .30 100 0.045 300 .37 150 0.054 400 .46 200 0.066 500 .58 250 0.081 600 .73 300 0.098 Apparent thermal conductivity curve determined in accordance with ASTM Practice C 1045 with data obtained by ASTM Test Method C177. Values are nominal, subject to normal testing and manufacturing tolerances. Thermal Performance Thickness (inches) Operating Temperature, F 450 550 650 750 850 HL ST HL ST HL ST HL ST HL ST 2 58 141 84 162 3 40 125 58 141 80 159 4 31 116 44 129 61 144 82 160 107 179 5 25 110 36 121 50 134 66 148 86 164 6 21 106 30 1 6 42 126 56 139 72 153 7 18 103 26 1 2 36 121 48 132 62 145 8 16 101 23 108 32 1 7 42 127 55 138 The above table provides approximate heat loss values (HL) Btu/hrft 2 F, and Surface Temperatures (ST), F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80F ambient temperature, still air, weathered aluminum jacket with emmitance of 0.2. 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 k, Btuin/(hrft. 2 F) 0 100 200 300 400 600 500 Mean Temperature, F Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. SCS Global Services provides independent verification of recycled content in building materials and verifies recycled content claims made by manufacturers. For more information, visit www.SCSglobalservices.com.

Previous Page
Next Page