Division 22 23 Ebook Page 113 Fiberglas TIW Product Data Sheet

Installation Fiberglas TIW Types I-HP and II-HP Insulations can be installed directly on heated flat and curved surfaces by attaching with welded pins or studs and finishing with sheet metal or metal mesh and insulating cement, then canvassed and painted. Pins with speed washers or studs and nuts should be installed on 16 (400mm) (maximum) spacing and not more than 4" (100mm) from the edge of the insulation. The insulation is normally impaled over the pins or studs and the enclosing sheet metal or metal mesh secured to the same fasteners. Joints of the sheet metal finish are offset from joints of the insulation. For temperatures over 400F (204C), good insulation practice suggests double layer application, with overlapping the layers regardless of insulation type. Single layer installation of any type of insulation material requires good workmanship to minimize heat loss and hot spots at insulation joints. Fiberglas TIW Types I-HP and II-HP Insulations may be installed in either single or multiple layers at all temperatures up to 1,000F (538C). Maximum allowable thicknesses at that temperature: TIW Type I-HP, 8" (216mm); TIW Type II-HP, 6 (152mm). Environmental and Sustainability Owens Corning is a worldwide leader in building material systems, insulation and composite solutions, delivering a broad range of high-quality products and services. Owens Corning is committed to driving sustainability by delivering solutions, transforming markets and enhancing lives. More information can be found at www.owenscorning.com. PANEL CONSTRUCTION METAL WIRE MESH OR EXPANDED METAL LATH FLUSH APPLICATION - METAL LAGGING RIBBED METAL LAGGING FLUSH APPLICATION - CANVASSED, PAINTED CENTENT 8 OZ. CANVAS AND PAINT Thermal Performance, ASTM C680 Thickness Operating Temperature, F ( C) 400 (204) 600 (316) 800 (427) 1,000 (538) in. (mm) HL ST HL ST HL ST HL ST TIW Type I-HP 1 25 109 182 241 275 435 394 699 533 2 51 61 143 136 201 249 281 409 379 3 76 43 126 95 171 174 230 287 305 4 102 32 116 73 153 133 201 221 262 5 127 27 110 59 141 108 182 179 233 6 152 22 106 49 133 91 168 151 213 7 178 19 102 43 126 79 157 130 198 8 203 17 99 38 121 69 150 114 186 TIW Type II-HP 1 25 81 160 167 225 289 306 453 404 2 51 45 128 92 167 159 219 251 282 3 76 31 115 63 145 109 183 173 229 4 102 23 107 48 131 84 162 132 198 5 127 19 109 39 123 68 148 106 180 6 152 16 99 33 117 57 139 89 167 The above table provides approximate heat loss values (HL), Btu/hrft2, and Surface Temperatures (ST), F, for flat surfaces. Values are based on horizontal heat flow, vertical flat surface, 80 F ambient temperature, still air, weathered aluminum jacket. To convert heat loss values to W/m2, multiply values by 3.15. To convert surface temperatures, use the formula: C = (F-32)/1.8. Thermal Conductivity Mean Temp. k Mean Temp. F Btuin/hrft 2 FC W/m C TIW Type I-HP 75 0.26 25 0.037 100 0.28 50 0.040 200 0.38 100 0.055 300 0.52 150 0.075 400 0.68 200 0.098 500 0.86 250 0.124 600 1.06 300 0.156 TIW Type II-HP 75 0.22 25 0.032 100 0.23 50 0.033 200 0.28 100 0.040 300 0.35 150 0.050 400 0.43 200 0.062 500 0.53 250 0.076 600 0.64 300 0.092 Values are nominal, subject to normal testing and manufacturing tolerances. Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. SCS Global Services provides independent verification of recycled content in building materials and verifies recycled content claims made by manufacturers. For more information, visit www.SCSglobalservices.com. LEED is a registered trademark of the U.S. Green Building Council. Certifications and Sustainable Features Certified by SCS Global Services to contain a minimum of 53% recycled glass content, 31% pre-consumer and 22% post-consumer Pub. No. 14729-P. Printed in U.S.A. January 2017. THE PINK PANTHER & 1964-2017 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. 2017 Owens Corning. All Rights Reserved. OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-GET-PINK www.owenscorning.com

Previous Page
Next Page