Division 22 23 Ebook Page 102 Air Handling Insulation Solutions Product Catalog

9 QuietR Duct Liner Board QuietR Duct Liner Board is a bonded board of glass fibers designed to be installed inside sheet metal ductwork or plenums with metal fasteners and adhesives. The smooth, fire-resistant airstream surface resists damage during installation and in service. It is ideal for use in large ducts and plenums where air velocities do not exceed 6,000 fpm (30.5 m/s). Key Features Outstanding thermal and acoustical performance Absorbs noise within the duct that helps create quiet and comfortable environments Tough, abuse-resistant surface which reduces installation costs because these products resist damage Cleanable surface with a black mat facing that provides a smooth, durable surface making it easy to clean the duct liners using methods and equipment described in North American Insulation Manufacturers Association (NAIMA) Publication AH122, Cleaning Fibrous Glass Insulated Duct Systems: Recommended Practice Does not support bacterial and fungal growth with an EPA registered biocide that protects the airstream surface from microbial growth Standards, Codes Compliance ASTM C1071; Type II Rigid Board NFPA 90A and 90B Compliant ICC Compliant California Title 24 SMACNA Application Standard for Duct Liners NAIMA Fibrous Glass Duct Liner Installation Standard (AH 124) Conforms to ASHRAE 62-2001 Meets requirements of ASTM C 1338, ASTM G 21 (fungi test), and ASTM G 22 (bacteria test) Availability QuietR Duct Liners are available in the following combinations of thicknesses and types: R-values, hrft 2 F/Btu (RSI, m 2 C/W) at 75F (24C) mean temperature Product Type and Thickness Nominal Density pcf (kg/m 3 ) 1.0 in (25mm) 2.0 in (51mm) QuietR Duct Liner Board 3.0 (48) 4.3 (0.76) 8.7 (1.53) QuietR Duct Liner Board is available in the following standard sizes: 1" x 48" x 96" (25mm x 1219mm x 2438mm), 2" x 48" x 96" (51mm x 1219mm x 2438mm). MTO available at Width: 48", Length: 24"-120". Physical Properties Property Test Method Value Operating Temperature ASTM C411 250F (121C) Maximum Air Velocity UL 181 Erosion Test ASTM C1071 6,000 fpm (30.5 m/s) Water Vapor Sorption ASTM C1104 <3% by weight at 120F (49C), 95% R.H. Fungi Resistance ASTM C1338 Meets requirements Fungi Resistance ASTM G21 Meets requirements Bacteria Resistance ASTM G22 Meets requirements Corrosiveness 1 ASTM C665 Corrosiveness Test Will not cause corrosion greater than caused by sterile cotton on aluminum or steel Thermal Conductivity k at 75F ( at 24C mean) ASTM C518 Btuin/hrft2F 0.23 W/mC (0.033) Surface Burning Characteristics 2 Flame Spread Smoke Developed ASTM E84, NFPA 255, UL 723, CAN/ULC S102 25 50 1. When wet, coated surfaces of QuietR Duct Liner Board in contact with galvanized steel may cause discoloration of the sheet metal. 2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E 84, NFPA 255, and CAN/ULC-S102. These standards should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.

Previous Page
Next Page